40 C.F.R. § 98.237

Current through May 31, 2024
Section 98.237 - [Effective 1/1/2025] Records that must be retained

Monitoring Plans, as described in § 98.3(g)(5) , must be completed by April 1, 2011. In addition to the information required by § 98.3(g) , you must retain the following records:

(a) Dates on which measurements were conducted.
(b) Results of all emissions detected and measurements.
(c) Calibration reports for detection and measurement instruments used.
(d) Inputs and outputs of calculations or emissions computer model runs used for engineering estimation of emissions.
(e) The records required under § 98.3(g)(2)(i) shall include an explanation of how company records, engineering estimation, or best available information are used to calculate each applicable parameter under this subpart.
(f) For each time a missing data procedure was used, keep a record listing the emission source type, a description of the circumstance that resulted in the need to use missing data procedures, the missing data provisions in § 98.235 that apply, the calculation or analysis used to develop the substitute value, and the substitute value.
(g) For each situation when you fail to fully conform with all cited provisions in either § 98.233(n)(1)(i) or (ii) for a period of 15 consecutive days and you utilized the Tier 3 default destruction and combustion efficiency values, you must document these periods when the non-conformance began, and the date when full conformance was re-established.

40 C.F.R. §98.237

75 FR 74488, Nov. 30, 2010, as amended at 76 FR 80590, Dec. 23, 2011; 79 FR 70424, Nov. 25, 2014
89 FR 42321, 1/1/2025