The CVS is calibrated using an accurate flowmeter and restrictor valve. Measurements of various parameters are made and related to flow through the unit. Procedures used by EPA for both PDP and CFV are outlined below. Other procedures yielding equivalent results may be used if approved in advance by the Administrator. After the calibration curve has been obtained, verification of the entire system can be performed by injecting a known mass of gas into the system and comparing the mass indicated by the system to the true mass injected. An indicated error does not necessarily mean that the calibration is wrong, since other factors can influence the accuracy of the system, e.g., analyzer calibration. A verification procedure is found in paragraph (c) of this section.
Calibration Data Measurements
Parameter | Symbol | Units | Tolerances |
Barometric pressure (corrected) | PB | in. Hg (kPa) | ±0.01 in. Hg (±0.034 kPa) |
Ambient temperature | TA | °F(°C) | ±0.5 °F (±0.28 °C) |
Air temperature into LFE | ETI | °F(°C) | ±0.25 °F (±0.14 °C) |
Pressure depression upstream of LFE | EPI | in. H2O (kPa) | ±0.05 in. H20 (±0.012 kPa) |
Pressure drop across the LFE matrix | EDP | in. H2O (kPa) | ±0.005 in. H2O (±0.001 kPa) |
Air temperature at CVS pump inlet | PTI | °F(°C) | ±0.5 °F (±0.3 °C) |
Pressure depression at CVS pump inlet | PPI | in. fluid (kPa) | ±0.05 in. fluid (±0.022 kPa) |
Specific gravity of manometer fluid (1.75 oil) | Sp. Gr. | ||
Pressure head at CVS pump outlet | PPO | in. fluid (kPa) | ±0.05 in. fluid (±0.022 kPa) |
Air temperature at CVS pump outlet (optional) | PTO | °F(°C) | ±0.5 °F (±0.28 °C) |
Pump revolutions during test period | N | Revs | ±1 Rev. |
Elapsed time for test period | t | sec | ±0.05 sec. |
Vo = (Qs/n) * (Tp/528) * (29.92/Pp)
Where:
Where:
Where:
Where:
Vo = Do - M(Xo)
n = A - B([DELTA] Pp)
Do, M, A, and B are the slope-intercept constants describing lines.
Where:
The calibration procedure described below establishes the value of the calibration coefficient at measured values of pressure, temperature and air flow.
Calibration Data Measurements
Parameter | Symbol | Units | Tolerances |
Barometric pressure (corrected) | Pb | Inches Hg (kPa) | ±.01 in Hg (±.034 kPa) |
Air temperature, flowmeter | ETI | °F (°C) | ±25 °F (±14 °C) |
Pressure depression upstream of LFE | EPI | Inches H2O (kPa) | ±.05 in H2O (±.012 kPa) |
Pressure drop across LFE matrix | EDP | Inches H2O (kPa) | ±.005 in H2O (±.001 kPa) |
Air flow | Qs | Ft3/min. (m3/min,) | ±.5 pct |
CFV inlet depression | PPI | Inches fluid (kPa) | ±.13 in fluid (±.055 kPa) |
CFV outlet pressure | PPO | Inches Hg (kPa) | ±0.05 in. Hg (±0.17 kPa)1 |
Temperature at venturi inlet | Tv | °F (°C) | ±0.5 °F (±0.28 °C) |
Specific gravity of manometer fluid (1.75 oil) | Sp. Gr |
1 Requirement begins August 20, 2001.
Where:
Where:
Where:
Pin-cal = Venturi inlet pressure (PPI in absolute pressure units), and
Pout-cal = Venturi outlet pressure (PPO in absolute pressure units), measured at the exit of the venturi diffuser outlet.
Where:
Pin-i and Pout-i are the venturi inlet and outlet pressures, in absolute pressure units, at each i-th interval during the emissions test.
40 C.F.R. §86.119-90