40 C.F.R. § 65.68-65 app Table 3 to Subpart D of Part 65

Current through May 31, 2024
Appendix Table 3 to Subpart D of Part 65 - TRE Parameters for HON Referencing Subparts [a]

Existing or new? Halogenated vent stream?Values of terms for TRE equation: TRE = A * [ B + C + D + E + F ]
A B C D E F Equation number
ExistingYes1/EHAP3.9950.05200Q0-0.001769H0.0009700ETOC33
No1/EHAP1.9350.3660Q0-0.007687H-0.000733ETOC34
1/EHAP1.4920.06267Q00.03177H-0.001159ETOC35
1/EHAP2.5190.01183Q00.01300H0.04790ETOC36
NewYes1/EHAP1.08950.01417Q0-0.000482H0.0002645ETOC37
No1/EHAP0.52760.0998Q0-0.002096H-0.0002000ETOC38
1/EHAP0.40680.0171Q00.008664H-0.000316ETOC39
1/EHAP0.68680.00321Q00.003546H0.01306ETOC40

a Use according to procedures outlined in § 65.64(h) .

40 C.F.R. 65.68-65 app Table 3 to Subpart D of Part 65