Where:
ERHAPt = total emission rate of organic HAP in vent stream, kilograms per hour (kg/hr) (pounds per hour (lb/hr)).
ERHAPj = emission rate of individual organic HAP in vent stream, kg/hr (lb/hr).
j = individual HAP.
m = number of individual HAP sampled in each test run.
Where:
ERsulft = total emission rate of sulfide in vent stream, kg/hr (lb/hr), as carbon disulfide.
ERCS2 = emission rate of carbon disulfide in vent stream, kg/hr (lb/hr).
ERH2S = emission rate of hydrogen sulfide in vent stream, kg/hr (lb/hr).
MCS2 = mass of carbon disulfide per mole of carbon disulfide, 76 kilograms per kilogram-mole (kg/kg-mol) (76 pounds per pound-mole (lb/lb-mol)).
MH2S = mass of hydrogen sulfide per mole of carbon disulfide, 68 kg/kg-mol (68 lb/lb-mol).
ERCOS = emission rate of carbonyl sulfide in vent stream, kg/hr (lb/hr).
MCOS = mass of carbonyl sulfide per mole of carbon disulfide, 120 kg/kg-mol (120 lb/lb-mol).
Where:
CE = control efficiency, percent.
ERi = total emission rate of organic HAP (ERHAPt) or sulfide (ERsulft) in the inlet vent stream of the control device, kg/hr (lb/hr).
ERo = total emission rate of organic HAP (ERHAPt) or sulfide (ERsulft) in the outlet vent stream of the control device, kg/hr (lb/hr).
40 C.F.R. §63.5535