Compliance alternative | Parameter to be monitored | Requirements |
Compliance Using Stripping Technology, Demonstrated through Periodic Sampling [§ 63.495(b) ] | Residual organic HAP content in each sample of crumb or latex | (1) If a stripper operated in batch mode is used, at least one representative sample is to be taken from every batch. (2) If a stripper operated in continuous mode is used, at least one representative sample is to be taken each operating day. |
Quantity of Material (weight of latex or dry crumb rubber) represented by each sample | (1) Acceptable methods of determining this quantity are production records, measurement of stream characteristics, and engineering calculations. | |
Compliance Using Stripping Technology, Demonstrated through Stripper Parameter Monitoring [§ 63.495(c) ] | At a minimum, temperature, pressure, steaming rates (for steam strippers), and some parameter that is indicative of residence time | (1) Establish stripper operating parameter levels for each grade in accordance with § 63.505(e) . (2) Continuously monitor stripper operating parameters. (3) If hourly average parameters are outside of the established operating parameter levels, a crumb or latex sample shall be taken in accordance with § 63.495(c)(3)(ii) . |
Determining Compliance Using Control or Recovery Devices [§ 63.496 ] | Parameters to be monitored are described in Table 3 of subpart G of this part | Comply with requirements listed in Table 3 of subpart G of this part, except for the requirements for halogenated vent stream scrubbers. |
40 C.F.R. 63 app Table 8 to Subpart U of Part 63