Table 1-Facility-wide Emission Limits for Facilities With Solvent Cleaning Machines
Solvents emitted | Facility-wide annual emission limits in kg-for general population degreasing machines | Facility-wide annual emission limit in kg for military depot maintenance facilities |
PCE onlya | 4,800 | 8,000 |
TCE only | 14,100 | 23,500 |
MC only | 60,000 | 100,000 |
Multiple solvents-Calculate the MC-weighted emissions using equation 1 | 60,000 | 100,000 |
a PCE emission limit calculated using CalEPA URE.
Note: In the equation, the facility emissions of PCE and TCE are weighted according to their carcinogenic potency relative to that of MC. The value of A is 12.5. The value for B is 4.25.
Where:
WE = Weighted 12-month rolling total emissions in kg (lbs).
PCE = 12-month rolling total PCE emissions from all solvent cleaning machines at the facility in kg (lbs).
TCE = 12-month rolling total TCE emission from all solvent cleaning machines at the facility in kg (lbs).
MC = 12-month rolling total MC emissions from all solvent cleaning machines at the facility in kg (lbs).
Where:
Eunit = the total halogenated HAP solvent emissions from the solvent cleaning machine during the most recent month i, (kilograms of solvent per month).
SAi = the total amount of halogenated HAP liquid solvent added to the solvent cleaning machine during the most recent month i, (kilograms of solvent per month).
LSRi = the total amount of halogenated HAP liquid solvent removed from the solvent cleaning machine during the most recent month i, (kilograms of solvent per month).
SSRi = the total amount of halogenated HAP solvent removed from the solvent cleaning machine in solid waste, obtained as described in paragraph (c)(3) of this section, during the most recent month i, (kilograms of solvent per month).
Where:
ETunit = the total halogenated HAP solvent emissions over the preceding 12 months, (kilograms of solvent emissions per 12-month period).
Eunit = halogenated HAP solvent emissions for each month (j) for the most recent 12 months (kilograms of solvent per month).
Where:
ETfacility = the total halogenated HAP solvent emissions over the preceding 12 months for all cleaning machines at the facility, (kilograms of solvent emissions per 12-month period).
ETunit = the total halogenated HAP solvent emissions over the preceding 12 months for each unit j, where i equals the total number of units at the facility (kilograms of solvent emissions per 12-month period).
40 C.F.R. §63.471