40 C.F.R. § RRRRR app Table 3 to Subpart RRRRR of Part 63

Current through May 31, 2024
Appendix Table 3 to Subpart RRRRR of Part 63 - Hydrogen Chloride and Hydrogen Fluoride Emission Limits for Indurating Furnaces

Table 3 to Subpart RRRRR of Part 63-Hydrogen Chloride and Hydrogen Fluoride Emission Limits for Indurating Furnaces

[As required in § 63.9590(a) , you must comply with each applicable hydrogen chloride and hydrogen fluoride emission limit in the following table:]

For . . .You must meet the following emission limits . . .
1. Indurating furnaces constructed or reconstructed before May 15, 2023Hydrogen chloride emissions must not exceed 4.6 * 10-2 lb/Long Ton of taconite pellets produced.
Hydrogen fluoride emissions must not exceed 1.2 * 10-2 lb/Long Ton of taconite pellets produced.
2. Indurating furnaces constructed or reconstructed on or after May 15, 2023Hydrogen chloride emissions must not exceed 4.4 * 10-4 lb/Long Ton of taconite pellets produced
Hydrogen fluoride emissions must not exceed 3.3 * 10-4 lb/Long Ton of taconite pellets produced.

40 C.F.R. RRRRR app Table 3 to Subpart RRRRR of Part 63

89 FR 16438, Mar. 6, 2024
89 FR 16438, 3/6/2024