Where:
X1 = The PM CPMS data points for the three runs constituting the performance test.
Y1 = The PM concentration value for the three runs constituting the performance test.
n = The number of data points.
Where:
R = The relative lb/ton-clinker per milliamp or digital equivalent for your PM CPMS.
Y1 = The three run average lb/ton-clinker PM concentration.
X1 = The three run average milliamp or digital equivalent output from your PM CPMS.
z = The milliamp or digital equivalent of your instrument zero determined from (b)(1)(iii)(A).
Where:
Ol = The operating limit for your PM CPMS on a 30-day rolling average, in milliamps or the digital equivalent.
L = Your source emission limit expressed in lb/ton clinker.
z = Your instrument zero in milliamps, or digital equivalent, determined from (b)(1)(iii)(A).
R = The relative lb/ton-clinker per milliamp, or digital equivalent, for your PM CPMS, from Equation 4.
Where:
X1 = The PM CPMS data points for all runs i.
n = The number of data points.
Oh = Your site specific operating limit, in milliamps or the digital equivalent.
Where:
Hpvi = The hourly parameter value for hour i.
n = The number of valid hourly parameter values collected over 30 kiln operating days.
Where:
ECm = Combined hourly emission rate of PM from the kiln and bypass stack and/or inline coal mill, lb/ton of kiln clinker production.
EK = Hourly emissions of PM emissions from the kiln, lb.
EB = Hourly PM emissions from the alkali bypass stack, lb.
EC = Hourly PM emissions from the inline coal mill stack, lb.
P = Hourly clinker production, tons.
Where:
Cks = Kiln stack concentration (ppmvd).
Qab = Alkali bypass flow rate (volume/hr).
Cab = Alkali bypass concentration (ppmvd).
Qcm = Coal mill flow rate (volume/hr).
Ccm = Coal mill concentration (ppmvd).
Qks = Kiln stack flow rate (volume/hr).
Where:
E30D = 30-day rolling emission rate of mercury, lb/MM tons clinker.
Ci = Concentration of mercury for operating hour i, [MICRO]g/scm.
Qi = Volumetric flow rate of effluent gas for operating hour i, where Ci and Qi are on the same basis (either wet or dry), scm/hr.
k = Conversion factor, 1 lb/454,000,000 [MICRO]g.
n = Number of kiln operating hours in the previous 30 kiln operating day period where both C and Qi qualified data are available.
P = Total runs from the previous 30 days of clinker production during the same time period as the mercury emissions measured, million tons.
Where:
Cks = Kiln stack concentration (ppmvd).
Qab = Alkali bypass flow rate (volume/hr).
Cab = Alkali bypass concentration (ppmvd).
Qcm = Coal mill flow rate (volume/hr).
Ccm = Coal mill concentration (ppmvd).
Qks = Kiln stack flow rate (volume/hr).
Where:
Xi = The HCl CPMS data points for the three (or six) runs constituting the performance test;
Yi = The HCl concentration value for the three (or six) runs constituting the performance test; and
n = The number of data points.
Where:
Xi = The HCl CPMS data points for the three runs constituting the mill on OR mill off performance test;
Yi = The HCl concentration value for the three runs constituting the mill on OR mill off performance test; and
n = The number of data points.
Where:
R = The relative performance test concentration per indicated ppm for your HCl CPMS;
Y1 = The average HCl concentration as ppmvd @7% O2 during the performance test;
X1 = The average indicated ppm output from your HCl CPMS; and
z = The ppm of your instrument zero determined from paragraph (b)(6)(v)(C)(1) of this section.
Where:
Ol = The operating limit for your HCl CPMS on a 30 kiln operating day average, as indicated ppm;
L = 3 ppmvd @7% O2;
z = Your instrument zero, determined from paragraph (b)(6)(v)(C)(1) of this section ; and
R = The relative performance test concentration per indicated ppm for your HCl CPMS, from Equation 11c.
Where:
Oh = Your site specific HCl CPMS operating limit, in indicated ppm.
Xi = The HCl CPMS data points for all runs i.
n = The number of data points.
Where:
30 kiln operating day parameter average = The average indicated value for the CPMS parameter over the previous 30 days of kiln operation;
Hpvi = The hourly parameter value for hour i; and
n = The number of valid hourly parameter values collected over 30 kiln operating days.
Where:
R = HCl CPMS operating limit;
b = Average indicated HCl CPMS value during mill on operations, ppm;
t = Fraction of operating time with mill on;
a = Average indicated HCl CPMS value during mill off operations ppm; and
(1-t) = Fraction of operating time with mill off.
Where:
x = The average THC CEMS value in ppmvw, as propane.
Xi = The THC CEMS data points in ppmvw, as propane, for all three test runs.
y = The average organic HAP value in ppmvd, corrected to 7 percent oxygen.
Yi = The organic HAP concentrations in ppmvd, corrected to 7 percent oxygen, for all three test runs.
n = The number of data points.
Where:
Tl = The 30-day operating limit for your THC CEMS, ppmvw, as propane.
y = The average organic HAP concentration from Eq. 12, ppmvd, corrected to 7 percent oxygen.
x = The average THC CEMS concentration from Eq. 12, ppmvw, as propane.
9 = 75 percent of the organic HAP emissions limit (12 ppmvd, corrected to 7 percent oxygen)
Where:
X1 = The THC CEMS data points for all runs i.
n = The number of data points.
Th = Your site specific operating limit, in ppmvw THC.
Where:
R = Operating limit as THC, ppmvw.
y = Average THC CEMS value during mill on operations, ppmvw.
t = Percentage of operating time with mill on.
x = Average THC CEMS value during mill off operations, ppmvw.
(1-t) = Percentage of operating time with mill off.
Where:
Hpvi = The hourly parameter value for hour i, ppmvw.
n = The number of valid hourly parameter values collected over 30 kiln operating days.
Where:
R = Operating limit as SO2, ppmv.
y = Average SO2 CEMS value during mill on operations, ppmv.
t = Percentage of operating time with mill on, expressed as a decimal.
x = Average SO2 CEMS value during mill off operations, ppmv.
1-t = Percentage of operating time with mill off, expressed as a decimal.
Where:
x = The average SO2 CEMS value in ppmv.
X1 = The SO2 CEMS data points in ppmv for the three runs constituting the performance test.
y = The average HCl value in ppmvd, corrected to 7 percent oxygen.
Y1 = The HCl emission concentration expressed as ppmvd, corrected to 7 percent oxygen for the threeruns constituting the performance test.
n = The number of data points.
Where:
R = The relative HCl ppmvd, corrected to 7 percent oxygen, per ppmv SO2 for your SO2 CEMS.
y = The average HCl concentration from Eq. 18 in ppmvd, corrected to 7 percent oxygen.
x = The average SO2 CEMS value from Eq. 18 in ppmv.
z = The instrument zero output ppmv value.
Where:
Ol = The operating limit for your SO2 CEMS on a 30-day rolling average, in ppmv.
L = Your source HCl emission limit expressed in ppmv corrected to 7 percent O2.
z = Your instrument zero in ppmv, determined from (1)(i).
R = The relative oxygen corrected ppmv HCl per ppmv SO2, for your SO2 CEMS, from Equation 19.
Where:
Hpvi = The hourly parameter value for hour i, ppmvw.
n = The number of valid hourly parameter values collected over 30 kiln operating days.
40 C.F.R. §63.1349