40 C.F.R. § 63.1662-63 app Table 2 to Subpart HHHHH of Part 63

Current through May 31, 2024
Appendix Table 2 to Subpart HHHHH of Part 63 - Emission Limits for Storage Tanks

As required in § 63.8010 , you must meet each emission limit in the following table that applies to your storage tanks.

For each . . .Then you must . . .
1. Group 1a storage tanka. Comply with the requirements of subpart WW of this part, except as specified in § 63.8010(b) ; or
b. Reduce total organic HAP emissions from the storage tank by [GREATER THAN EQUAL TO]90 percent by weight by venting emissions through a closed-vent system to any combination of control devices (excluding a flare); or
c. Reduce total organic HAP emissions from the storage tank by venting emissions from a non-halogenated vent stream through a closed-vent system to a flare.
2. Group 1b storage tanka. Comply with the requirements of subpart WW of this part, except as specified in § 63.8010(b) ; or
b. Reduce total organic HAP emissions from the storage tank by [GREATER THAN EQUAL TO]80 percent by weight by venting emissions through a closed-vent system to any combination of control devices (excluding a flare); or
c. Reduce total organic HAP emissions from the storage tank by venting emissions from a non-halogenated vent stream through a closed-vent system to a flare.

40 C.F.R. 63.1662-63 app Table 2 to Subpart HHHHH of Part 63