40 C.F.R. § 63.1662-63 app Table 2 to Subpart GGGGG of Part 63

Current through May 31, 2024
Appendix Table 2 to Subpart GGGGG of Part 63 - Control Levels as Required by Section 63.7895(a) for Tanks Managing Remediation Material With a Maximum HAP Vapor Pressure Less Than 76.6 kPa

If your tank design capacity is . . .And the maximum HAP vapor pressure of the remediation material placed in your tank
is . . .
Then your tank must use . . .
1. Less than 38 m3Less than 76.6 kPaTank Level 1 controls under § 63.7895(b) .
2. At least 38 m3 but less than 151 m3Less than 13.1 kPaTank Level 1 controls under § 63.7895(b) .
3. 151 m3 or greaterLess than 0.7 kPaTank Level 1 controls under § 63.7895(b) .
4. at least 38 m3 but less than 151 m313.1 kPa or greaterTank Level 2 controls under § 63.7895(c) .
5. 151 m3 or greater0.7 kPa or greaterTank Level 2 controls under § 63.7895(c)

40 C.F.R. 63.1662-63 app Table 2 to Subpart GGGGG of Part 63