You must meet, as applicable, the performance testing requirements specified in paragraph (a) of this section, the monitoring requirements specified in paragraph (b) of this section, the air pollution control device inspections requirements specified in paragraph (c) of this section, and the bypass stack provisions specified in paragraph (d) of this section.
Where:
Cadj = Pollutant concentration adjusted to 7 percent oxygen.
Cmeas = Pollutant concentration measured on a dry basis.
(20.9 - 7) = 20.9 percent oxygen - 7 percent oxygen (defined oxygen correction basis).
20.9 = Oxygen concentration in air, percent.
%O2 = Oxygen concentration measured on a dry basis, percent.
40 C.F.R. §62.16015