40 C.F.R. § 62 app Table 3 to Subpart FFF of Part 62

Current through May 31, 2024
Appendix Table 3 to Subpart FFF of Part 62 - Municipal Waste Combustor Operating Requirements

Municipal waste combustor technologyCarbon monoxide emissions level (parts per million by volume)a Averaging time (hrs)b
Mass burn waterwall1004
Mass burn refractory1004
Mass burn rotary refractory10024
Mass burn rotary waterwall25024
Modular starved air504
Modular excess air504
Refuse-derived fuel stoker20024
Fluidized bed, mixed fuel (wood/refuse-derived fuel)200c 24
Bubbling fluidized bed combustor1004
Circulating fluidized bed combustor1004
Pulverized coal/refuse-derived fuel mixed fuel-fired combustor1504
Spreader stoker coal/refuse-derived fuel mixed fuel-fired combustor20024

a Measured at the combustor outlet in conjunction with a measurement of oxygen concentration, corrected to 7 percent oxygen, dry basis. Calculated as an arithmetic average.

b Averaging times are 4-hour or 24-hour block averages.

c 24-hour block average, geometric mean.

40 C.F.R. 62 app Table 3 to Subpart FFF of Part 62

69 FR 42121, July 14, 2004