Operating parameters to be monitored | Minimum frequency | Control system | |||
Data measurement | Data recording | Dry scrubber followed by fabric filter | Wet scrubber | Dry scrubber followed by fabric filter and wet scrubber | |
Maximum operating parameters: | |||||
Maximum charge rate | Continuous | 1 * hour | |||
Maximum fabric filter inlet temperature | Continuous | 1 * minute | |||
Maximum flue gas temperature | Continuous | 1 * minute | |||
Minimum operating parameters: | |||||
Minimum secondary chamber temperature | Continuous | 1 * minute | |||
Minimum dioxin/furan sorbent flow rate | Hourly | 1 * hour | |||
Minimum HCI sorbent flow rate | Hourly | 1 * hour | |||
Minimum mercury (Hg) sorbent flow rate | Hourly | 1 * hour | |||
Minimum pressure drop across the wet scrubber or minimum horsepower or amperage to wet scrubber | Continuous | 1 * minute | |||
Minimum scrubber liquor flow rate | Continuous | 1 * minute | |||
Minimum scrubber liquor pH | Continuous | 1 * minute |
40 C.F.R. 60 app Table 3 to Subpart Ec of Part 60