If . . . | Then . . . |
(1) There is sufficient structural redundancy to prevent catastrophic failure of the platform or structure under consideration, | The results of the fatigue analysis must indicate a minimum calculated life of twice the design life of the platform. |
(2) There is not sufficient structural redundancy to prevent catastrophic failure of the platform or structure, | The results of a fatigue analysis must indicate a minimum calculated life or three times the design life of the platform. |
(3) The desirable degree of redundancy is significantly reduced as a result of fatigue damage, | The results of a fatigue analysis must indicate a minimum calculated life of three times the design life of the platform. |
30 C.F.R. §250.908