30 C.F.R. § 75.326

Current through September 30, 2024
Section 75.326 - Mean entry air velocity

In exhausting face ventilation systems, the mean entry air velocity shall be at least 60 feet per minute reaching each working face where coal is being cut, mined, drilled for blasting, or loaded, and to any other working places as required in the approved ventilation plan. A lower mean entry air velocity may be approved in the ventilation plan if the lower velocity will maintain methane and respirable dust concentrations in accordance with the applicable levels. Mean entry air velocity shall be determined at or near the inby end of the line curtain, ventilation tubing, or other face ventilation control devices.

30 C.F.R. §75.326

61 FR 9828, Mar. 11, 1996; 61 FR 29288, June 10, 1996