30 C.F.R. § 57.6407

Current through September 30, 2024
Section 57.6407 - Circuit testing

A blasting galvanometer or other instrument designed for testing blasting circuits shall be used to test the following:

(a) In surface operations-
(1) Continuity of each electric detonator in the blasthole prior to stemming and connection to the blasting line;
(2) Resistance of individual series or the resistance of multiple balanced series to be connected in parallel prior to their connection to the blasting line;
(3) Continuity of blasting lines prior to the connection of electric or electronic detonator series; and
(4) Total blasting circuit resistance prior to connection to the power source.
(b) In underground operations-
(1) Continuity of each electric detonator series; and
(2) Continuity of blasting lines prior to the connection of electric or electronic detonators.

30 C.F.R. §57.6407

61 FR 36801, July 12, 1996, as amended at 85 FR 2027, Jan. 14, 2020
85 FR 2027, 3/16/2020