Section 305.10 - Determinations of capacityThe capacity of covered products shall be determined as follows:
(a)Refrigerators and refrigerator-freezers. The capacity shall be the total refrigerated volume (VT) in cubic feet, rounded to the nearest one-tenth of a cubic foot, as determined according to appendix A to 10 CFR part 430 , subpart B.(b)Freezers. The capacity shall be the total refrigerated volume (VT) in cubic feet, rounded to the nearest one-tenth of a cubic foot, as determined according to appendix B to 10 CFR part 430 , subpart B.(c)Dishwashers. The capacity shall be the place-setting capacity, determined according to appendix C to 10 CFR part 430 , subpart B.(d)Water heaters. The capacity shall be the rated storage volume and first hour rating (for storage-type models), and gallons per minute (for instantaneous-type models), as determined according to appendix E to 10 CFR part 430 , subpart B.(e)Pool heaters. The capacity shall be the heating capacity in Btu's per hour, rounded to the nearest 1,000 Btu's per hour, as determined according to appendix P to 10 CFR part 430 , subpart B.(f)Room air conditioners and portable air conditioners. The capacity for room air conditioners and portable air conditioners shall be determined according to 10 CFR part 430 , subpart B, with rounding determined in accordance with 10 CFR part 430 .(g)Clothes washers. The capacity shall be the tub capacity as determined according to Department of Energy test procedures in 10 CFR part 430 , subpart B, expressed in terms of "Capacity (tub volume)" in cubic feet, rounded to the nearest one-tenth of a cubic foot, and the capacity class designations "standard" or "compact."(h)Furnaces. The capacity shall be the heating capacity in Btu's per hour, rounded to the nearest 1,000 Btu's per hour, as determined according to appendix N to 10 CFR part 430 , subpart B.(i)Central air conditioners, cooling. The capacity shall be the cooling capacity in Btu's per hour, as determined according to appendix M to 10 CFR part 430 , subpart B, rounded to the nearest 100 Btu's per hour for capacities less than 20,000 Btu's per hour; to the nearest 200 Btu's per hour for capacities between 20,000 and 37,999 Btu's per hour; and to the nearest 500 Btu's per hour for capacities between 38,000 and 64,999 Btu's per hour.(j)Central air conditioners, heating. The capacity shall be the heating capacity in Btu's per hour, as determined according to appendix M to 10 CFR part 430 , subpart B, rounded to the nearest 100 Btu's per hour for capacities less than 20,000 Btu's per hour; to the nearest 200 Btu's per hour for capacities between 20,000 and 37,999 Btu's per hour; and to the nearest 500 Btu's per hour for capacities between 38,000 and 64,999 Btu's per hour.(k)Fluorescent lamp ballasts. The capacity shall be the ballast input voltage, as determined according to appendix Q to 10 CFR part 430 , subpart B.(l)Ceiling fans. The capacity shall be the airflow in cubic feet per minute as determined according to appendix U of 10 CFR part 430 , subpart B.59 FR 34033, July 1, 1994, as amended at 59 FR 49564, Sept. 28, 1994; 70 FR 3875, Jan. 27, 2005; 73 FR 63067, Oct. 23, 2008; 78 FR 43981, July 23, 2013; 79 FR 77870, Dec. 29, 2014; 80 FR 67299, Nov. 2, 2015; 81 FR 7202, Feb. 11, 2016; 81 FR 63646, Sept. 15, 2016; 83 FR 7596, Feb. 22, 2018. Redesignated at 84 FR 58029, Oct. 30, 2019; 86 FR 9282, Feb. 12, 2021; 87 FR 61467, Oct. 12, 2022 81 FR 7202, 2/11/2016; 83 FR 7596, 5/23/2018; 84 FR 58029, 11/29/2019; 86 FR 9282, 10/1/2022; 87 FR 61467, 1/10/2023