14 C.F.R. § 29.1125

Current through May 31, 2024
Section 29.1125 - Exhaust heat exchangers

For reciprocating engine powered rotorcraft the following apply:

(a) Each exhaust heat exchanger must be constructed and installed to withstand the vibration, inertia, and other loads to which it would be subjected in operation. In addition-
(1) Each exchanger must be suitable for continued operation at high temperatures and resistant to corrosion from exhaust gases;
(2) There must be means for inspecting the critical parts of each exchanger;
(3) Each exchanger must have cooling provisions wherever it is subject to contact with exhaust gases; and
(4) No exhaust heat exchanger or muff may have stagnant areas or liquid traps that would increase the probability of ignition of flammable fluids or vapors that might be present in case of the failure or malfunction of components carrying flammable fluids.
(b) If an exhaust heat exchanger is used for heating ventilating air used by personnel-
(1) There must be a secondary heat exchanger between the primary exhaust gas heat exchanger and the ventilating air system; or
(2) Other means must be used to prevent harmful contamination of the ventilating air.

14 C.F.R. §29.1125

Doc. No. 5084, 29 FR 16150, Dec. 3, 1964, as amended by Amdt. 29-12, 41 FR 55473, Dec. 20, 1976; Amdt. 29-41, 62 FR 46173, Aug. 29, 1997