10 C.F.R. § 504 app II to Part 504

Current through September 30, 2024
Appendix II to Part 504 - Fuel Price Computation

(a) Introduction. This appendix provides the equations and parameters needed to specify the price of the delivered fuels to be used in the cost calculations associated with parts 503 and 504 of these regulations. The delivered price of the fuel to be used to calculate delivered fuel expenses must reflect

(1) the price of each fuel at the time of the petition, and

(2) the effects of future real price increases for each fuel. The delivered price of an alternate fuel used to calculate delivered fuel expenses must reflect the petitioner's delivered price of the alternate fuel and the effects of real increases in the price of that alternate fuel. Paragraphs (b), (c) and (d) below provide the procedure to: (1) Calculate fuel price and inflation indices; (2) account for projected real increases in fuel prices when planning to burn one or more than one fuel; and (3) account for projected real increases in the price of the alternate fuel. Table II-1 of this appendix (See paragraph (b)) contains example fuel price and inflation indices based on the latest data appearing in the Energy Information Administration's (EIA) Annual Energy Outlook (AEO).

The fuel price and inflation indices will change yearly with the publication of the AEO. Revisions shall become effective after final publication. However, the relevant set of parameters for a specific petition for exemption will be the set in effect at the time the petition is submitted or the set in effect at the time a decision is rendered, whichever is more favorable to the petitioner.

(b) Computation of Fuel Price and Inflation Indices.

(1) the Petitioner is responsible for computing the annual fuel price and inflation indices by using Equation II-1 and Equation II-2, respectively. The petitioner may compute the fuel price index specified in Equation II-1 or use his own price index. However, if he uses his own price index, the source or the derivation of the index must be fully documented and be contained in the evidential summary.

EQ II-2 is:

View Image

where:

PXVi = The fuel price index for each fuel in year i. Pi = Price of fuel in year i.

Po = Price of fuel in base year.

EQ II-2 is:

View Image

where:

IXi = The inflation index in year i.

GXi = The NIPA GNP price deflator for year i.

GXo = The NIPA GNP price deflator for the base year.

(2) The parameters to be used in EQ II-1 are the Base Case fuel price projections found in EIA's current AEO.

(3) When computing annual inflation indices, the petitioner is to use the Base Case National Macroeconomic Indicators (NIPA GNP Price Deflator) contained in EIA's current AEO. If necessary, the petitioner must rebase the projection to the same year used for the fuel price projections. For example, in 1989 AEO projects the price deflator in 1982 dollars; this must be rebased to the year in which the petition is filed. The methodology used to rebase the inflation indices must follow standard statistical procedures and must be fully documented within the petition. This index will remain frozen at the last year of the AEO's projection for the remainder of the unit'(s) useful life.

(4) Table II-1 is provided as an example of the application of equations II-1 and II-2. This table contains annual fuel price indices for distillate oil, residual oil, natural gas, and coal. It also contains annual inflation indices. These values were computed from information contained in Table A3 and Table A11 of EIA's AEO, 1989.

Table II-1: Price and Inflation Indices for use in the Cost Calculations

Year Distillate (DPX) Residual (RPX) Natural gas (GPX)Coal (CPX) Inflation (IX)
19861.00001.00001.00001.00001.0000
19870.98101.21340.95080.92311.0334
19880.94290.94070.89340.88761.0658
19890.89290.93280.90570.86391.1054
19900.99051.01190.92210.91121.1607
19911.03811.07510.93440.91721.2204
19921.09291.13441.02050.92311.2836
19931.15951.22921.11480.93491.3512
19941.22861.32411.18440.94671.4214
19951.30001.41501.27050.95271.4960
19961.40001.54151.40160.95861.5768
19971.47621.64031.49180.97041.6585
19981.54521.72731.56150.97631.7410
19991.61431.79051.64750.98821.8235
20001.66901.83401.70490.99411.9025
20011.6690I.83401.70490.99411.9025
20021.66901.83401.70490.99411.9025
20031.66901.83401.70490.99411.9025
20041.66901.83401.70490.99411.9025
20051.66901.83401.70490.99411.9025
20061.66901.83401.70490.99411.9025
20071.66901.83401.70490.99411.9025
20081.66901.84301.70490.99411.9025
20091.66901.83401.70490.99411.9025
20101.66901.83401.70490.99411.9025

(C) Fuel Price Computation. (1) The delivered price of the proposed fuel to be burned (FPBi) must reflect the real escalation rate of the proposed fuel, and must be computed with Equation EQ II-3.

EQ-II-3 is: FPBi = MPB [PXi]

where:

FPBi = Price of the proposed fuel (distillate oil, residual oil, or natural gas) in year i.

MPB = The current delivered market price of the proposed fuel.

PXi = The fuel price index value in year i, computed with Equation II-1.

or:

(2) When planning to use more than one fuel in the proposed unit(s), the petitioner must use Equation II-1 and Equation II-3 to calculate the annual fuel price of each fuel to be used. The petitioner then must estimate the proportion of each fuel to be burned annually over the useful life of the unit(s). With these proportions and the respective annual fuel prices for each fuel, the petitioner must compute an annual weighted average fuel price. The methodology used to calculate the weighted average fuel price must follow standard statistical procedures and be fully documented within the petition.

(d) Fuel Price Computation-Alternate Fuel. The delivered price of alternate fuel (PFAi) must reflect the real escalation rate of alternate fuel and must be computed with Equation II-4.

Equation II-4 is:

PFAi = APF * apxi

where:

PFA = The price of the alternate fuel in year i.

APF-i = The current market price of the alternate fuel f.o.b. the facility).

APXi = The alternate fuel price index value for year i, computed with Equation II-1.

In most cases the alternate fuel will be coal. The petitioner must use Equation II-1 (paragraph (b)) to compute the escalation rate (APXi). If an alternate fuel other than coal is proposed the source or the derivation of the index must be fully documented and be contained in the evidential summary.

10 C.F.R. 504 app II to Part 504

54 FR 52896, Dec. 22, 1989