10 C.F.R. § 435.201

Current through November 30, 2024
Section 435.201 - Scope 1 Fossil fuel-generated energy consumption determination
(a) The Scope 1 fossil fuel-generated energy consumption of a proposed design is calculated as follows:

Equation: Scope 1 Fossil Fuel-Generated Energy Consumption = Direct Fossil Fuel Consumption of Proposed Building/Floor Area

Where:

Direct Scope 1 Fossil Fuel-Generated Energy Consumption of Proposed Building equals the total site Scope 1 fossil fuel-generated energy consumption of the proposed building calculated in accordance with the method required in § 435.5(d) , and measured in thousands of British thermal units per year (kBtu/yr), except that this term does not include fossil fuel consumption for emergency electricity generation. Agencies must include all on-site fossil fuel use or Scope 1 emissions associated with non-emergency generation from backup generators (such as those for peak shaving or peak shifting). Any energy generation or Scope 1 emissions associated with biomass fuels are excluded. Any emissions associated with natural gas for alternatively fueled vehicles ("AFVs") (or any other alternative fuel defined at 42 U.S.C. 13211 that is provided at a Federal building) is excluded. For buildings with manufacturing or industrial process loads, such process loads shall be accounted for in the analysis for the building's fossil fuel consumption and GHG emissions, but the process loads are not subject to the phase down targets.

Floor Area is the floor area of the structure that is enclosed by exterior walls, including finished or unfinished basements, finished or heated space in attics, and garages if they have an uninsulated wall in common with the house. Not included are crawl spaces, and sheds and other buildings that are not attached to the house.

10 C.F.R. §435.201

89 FR 35434 , 7/15/2024