10 C.F.R. § 429.51

Current through November 30, 2024
Section 429.51 - Commercial pre-rinse spray valves
(a)Sampling plan for selection of units for testing.
(1) The requirements of § 429.11 apply to commercial prerinse spray valves; and
(2) For each basic model of commercial prerinse spray valve, a sample of sufficient size must be randomly selected and tested to ensure that any represented value of flow rate must be greater than or equal to the higher of:
(i) The mean of the sample, where:

View Image

and, x is the sample mean;

n is the number of samples; and

xi is the ith sample; Or,

(ii) The upper 95-percent confidence limit (UCL) of the true mean divided by 1.10, where:

View Image

and, x is the sample mean;

s is the sample standard deviation;

n is the number of samples; and

t0.95 is the t statistic for a 95-percent two-tailed confidence interval with n-1 degrees of freedom (from Appendix A of this subpart).

(b)Certification reports.
(1) The requirements of § 429.12 are applicable to commercial prerinse spray valves; and
(2) Pursuant to § 429.12(b)(13) , a certification report must include the following public product-specific information: The flow rate, in gallons per minute (gpm), rounded to the nearest 0.01 gpm, and the corresponding spray force, in ounce-force (ozf), rounded to the nearest 0.1 ozf.

10 C.F.R. §429.51

76 FR 12451 , Mar. 7, 2011; 76 FR 24779 , May 2, 2011, as amended at 78 FR 62986 , Oct. 23, 2013; 80 FR 81453 , Dec. 30, 2015; 81 FR 4801 , Jan. 27, 2016
81 FR 4801 , 1/27/2016