10 C.F.R. § 429.48

Current through May 31, 2024
Section 429.48 - Illuminated exit signs
(a)Sampling plan for selection of units for testing.
(1) The requirements of § 429.11 are applicable to illuminated exit signs; and
(2) For each basic model of illuminated exit sign selected for testing, a sample of sufficient size shall be randomly selected and tested to ensure that-
(i) Any represented value of input power demand or other measure of energy consumption of a basic model for which consumers would favor lower values shall be greater than or equal to the higher of:
(A) The mean of the sample, where:

View Image

Or,

(B) The upper 95 percent confidence limit (UCL) of the true mean divided by 1.10, where:

View Image

and

(ii) Any represented value of the energy efficiency or other measure of energy consumption of a basic model for which consumers would favor higher values shall be less than or equal to the lower of:
(A) The mean of the sample, where:

View Image

Or,

(B) The lower 95 percent confidence limit (LCL) of the true mean divided by 0.90, where:

View Image

(b)Certification reports.
(1) The requirements of § 429.12 are applicable to illuminated exit signs; and
(2) Pursuant to § 429.12(b)(13) , a certification report shall include the following public product-specific information: The input power demand in watts (W) and the number of faces.

10 C.F.R. §429.48

76 FR 12451, Mar. 7, 2011; 76 FR 24778, May 2, 2011