Point of Operation Guarding Figure G-8
Explanation of Above Diagram:
This diagram shows the accepted safe openings between the bottom edge of a guard and feed table at various distances from the point of operation.
The minimum guarding line is 1/2 -inch from the point of operation. The various openings are such that with average size hands, an operator's fingers will not reach the point of operation.
After installation of point of operation guards and before a job is released for operation, a check should be made to verify that the guard will prevent the operator's hands from reaching the point of operation.
Table G-3
Distance of Opening from Point of Operation Hazard (Inches) | Maximum Width of Opening (Inches) | |
1/2 | to 1 1/2.......................... | ..........................1/4 |
1 1/2 | to 2 1/2 .......................... | ..........................3/8 |
2 1/2 | to 3 1/2 .......................... | ..........................1/2 |
3 1/2 | to 5 1/2 .......................... | ..........................5/8 |
5 1/2 | to 6 1/2 .......................... | ..........................3/4 |
6 1/2 | to 7 1/2 .......................... | ..........................7/8 |
7 1/2 | to 12 1/2 .......................... | ..........................1 1/4 |
12 1/2 | to 15 1/2 .......................... | ..........................1 1/2 |
15 1/2 | to 17 1/2 .......................... | ..........................1 7/8 |
17 1/2 | to 31 1/2 .......................... | ..........................2 1/8 |
Refer to Table G-1 in Section 3944 for the maximum width of openings permitted in guards at various distances from the moving parts of power transmission equipment, prime movers, machines and machine parts.
Cal. Code Regs. Tit. 8, § 4186
2. Amendment of subsection (b) and new Figure G-8 and Table G-3 filed 11-18-76; effective thirtieth day thereafter (Register 76, No. 47).
3. New subsection (c) filed 4-28-81; effective thirtieth day thereafter (Register 81, No. 18).
4. Amendment of subsections (b), (c), Figure G-8 and Table G-3 filed 10-31-85; effective thirtieth day thereafter (Register 85, No. 44).
5. Change without regulatory effect providing a more legible copy of Figure G-8 with no amendments filed 3-13-2000 pursuant to section 100, title 1, California Code of Regulations (Register 2000, No. 11).
6. Change without regulatory effect providing more legible illustration for Figure G-8 filed 2-18-2009 pursuant to section 100, title 1, California Code of Regulations (Register 2009, No. 8).
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
2. Amendment of subsection (b) and new Figure G-8 and Table G-3 filed 11-18-76; effective thirtieth day thereafter (Register 76, No. 47).
3. New subsection (c) filed 4-28-81; effective thirtieth day thereafter (Register 81, No. 18).
4. Amendment of subsections (b), (c), Figure G-8 and Table G-3 filed 10-31-85; effective thirtieth day thereafter (Register 85, No. 44).
5. Change without regulatory effect providing a more legible copy of Figure G-8 with no amendments filed 3-13-2000 pursuant to section 100, title 1, California Code of Regulations (Register 2000, No. 11).
6. Change without regulatory effect providing more legible illustration for Figure G-8 filed 2-18-2009 pursuant to section 100, title 1, California Code of Regulations (Register 2009, No. 8).