Cal. Code Regs. tit. 25 § 4517.2

Current through Register 2024 Notice Reg. No. 39, September 27, 2024
Section 4517.2 - Gas Piping/Tubing - Expandable or Multiple Commercial Modulars

Where fuel gas piping is to be installed in more than one (1) section of an expandable or multiple-section commercial modular, the design and construction shall comply with all of the following:

(a) There shall be only one (1) point of crossover between each section, which shall be readily accessible from the exterior of the commercial modular.
(b) The connector between sections shall be of approved pipe or a listed flexible connector for exterior use and sized in accordance with Section 4517.3 of this subarticle.
(c) Protective caps or plugs shall be permanently attached to the unit by means of a metal chain and used to seal the system when not in use.

Cal. Code Regs. Tit. 25, § 4517.2

1. New section filed 9-19-2011; operative 10-19-2011 (Register 2011, No. 38).

Note: Authority cited: Section 18015, Health and Safety Code. Reference: Section 18025, Health and Safety Code.

1. New section filed 9-19-2011; operative 10-19-2011 (Register 2011, No. 38).