Table 2433-1 | |||||
General Roof Live Load Requirements for Accessory Buildings and Structures and Building Components | |||||
Region I | Region II | Region III | |||
Roof Live | Roof Live | Roof Live | |||
Elevation | Load | Elevation | Load | Elevation | Load |
All | 0-3000 ft | 20 psf | 0-2000 ft | 20 psf | |
Elevations | 20 psf | 3001-3500 ft | 30 psf | 2001-3000 ft | 30 psf |
3501-5000 ft | 60 psf | 3001-4000 ft | 60 psf | ||
4001-5000 ft | 80 psf |
Table 2433-1 shall apply except where either greater or lesser snow loads have been established through survey of the region, and approved by the department.
Alameda, Butte, Colusa, Contra Costa, Del Norte, Glenn, Humboldt, Imperial, Kings, Lake, Los Angeles, Marin, Mendocino, Merced, Monterey, Napa, Orange, Sacramento, San Benito, San Diego, San Francisco, San Joaquin, San Luis Obispo, San Mateo, Santa Barbara, Santa Clara, Santa Cruz, Solano, Sonoma, Stanislaus, Sutter, Ventura, Yolo.
Amador, Fresno, Inyo, Kern, Modoc, Riverside, San Bernardino, Siskiyou.
Alpine, Calaveras, El Dorado, Lassen, Madera, Mariposa, Mono, Nevada, Placer, Plumas, Shasta, Sierra, Tehama, Trinity, Tulare, Tuolumne, Yuba.
Cal. Code Regs. Tit. 25, § 2433
Note: Authority cited: Section 18865, Health as Safety Code. Reference: Section 18871.3, Health and Safety Code.