Current through Register 2024 Notice Reg. No. 50, December 13, 2024
Section 2352 - Electrical Feeder Assembly(a) A recreational vehicle or camping cabin shall be connected to the lot service equipment by one of the following means:(1) A listed power supply cord approved for mobilehome or recreational vehicle use.(2) A power supply cord bearing the following markings: Type SO, ST, or STO. The cord shall not be spliced.(b) The male attachment plug shall conform with provisions of Articles 550 or 551 of the California Electrical Code.(c) The conductors shall be sized for the electrical load shown on the unit's electrical label.(d) In the absence of an electrical label on the unit or the unit manufacturer's approved installation instructions, the conductors shall be sized in accordance with the calculated load as determined by the provisions of the California Electrical Code, Articles 1, 2, and 3.(e) Only one (1) power supply connection to a unit shall be permitted.(f) Power supply cords shall not be buried or encased in concrete.Cal. Code Regs. Tit. 25, § 2352
1. New section filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28). Note: Authority cited: Section 18865, Health and Safety Code. Reference: Sections 18871 and 18873.3, Health and Safety Code.
1. New section filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).