NOTE: An accessory structure located beneath another accessory structure (e.g., a porch which is located beneath an awning) is excluded from the snow load requirements of this section when the overlying accessory structure meets the requirements of this section.
TABLE 1433-1 | |||||
General Roof Live Load Requirements for Accessory Buildings or Structures and Building Components | |||||
Region I | Region II | Region III | |||
Roof Live | Roof Live | Roof Live | |||
Elevation | Load | Elevation | Load | Elevation | Load |
All | |||||
Elevations | 20 psf | 0-3000 ft | 20 psf | 0-2000 ft | 20 psf |
3001-3500 ft | 30 psf | 2001-3000 ft | 30 psf | ||
3501-5000 ft | 60 psf | 3001-4000 ft | 60 psf |
Table 1433-1 shall apply except where either greater or lesser snow loads have been established through survey of the region, and approved by the department.
Alameda, Butte, Colusa, Contra Costa, Del Norte, Glenn, Humboldt, Imperial, Kings, Lake, Los Angeles, Marin, Mendocino, Merced, Monterey, Napa, Orange, Sacramento, San Benito, San Diego, San Francisco, San Joaquin, San Luis Obispo, San Mateo, Santa Barbara, Santa Clara, Santa Cruz, Solano, Sonoma, Stanislaus, Sutter, Ventura, Yolo.
Amador, Fresno, Inyo, Kern, Modoc, Riverside, San Bernardino, Siskiyou.
Alpine, Calaveras, El Dorado, Lassen, Madera, Mariposa, Mono, Nevada, Placer, Plumas, Shasta, Sierra, Tehama, Trinity, Tulare, Tuolumne, Yuba.
Cal. Code Regs. Tit. 25, § 1433
2. Amendment of subsection (a), Table 1433-1, subsection (b) and NOTE filed 12-26-2006; operative 1-2-2007 pursuant to Government Code section 11343.4 (Register 2006, No. 52).
Note: Authority cited: Sections 18300 and 18610, Health and Safety Code. Reference: Section 18552, Health and Safety Code.
2. Amendment of subsection (a), Table 1433-1, subsection (b) and Note filed 12-26-2006; operative 1-2-2007 pursuant to Government Code section 11343.4 (Register 2006, No. 52).