Cal. Code Regs. tit. 25 § 1358

Current through Register 2024 Notice Reg. No. 44, November 1, 2024
Section 1358 - Drain, Unit
(a) An MH-unit shall be connected to the lot drain inlet by means of a drain connector consisting of approved pipe not less than schedule 40, with listed and approved fittings and connectors, and shall not be less in size than the MH-unit drain outlet. A listed and approved flexible connector shall be provided at the lot drain inlet end of the pipe.
(b) Drain connectors and fittings for recreational vehicles shall be listed and approved for drain and waste.
(c) Recreational vehicles located in a park for more than three (3) months, or units with plumbing that are not self contained, shall have a drain connector complying with subsection (a).
(d) All drain connectors and fittings shall be maintained with a grade not less than one-eighth ( 1/8) inch per foot. A drain connector shall be gas-tight and no longer than necessary to make the connection between the unit's drain outlet and the drain inlet on the lot.

Cal. Code Regs. Tit. 25, § 1358

1. Amendment of section heading and section filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).

Note: Authority cited: Section 18300, Health and Safety Code. Reference: Sections 18550, 18613 and 18630, Health and Safety Code.

1. Amendment of section heading and section filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).