Cal. Code Regs. tit. 25 § 1274

Current through Register 2024 Notice Reg. No. 45, November 8, 2024
Section 1274 - Lot Water Service Outlet
(a) Each lot shall be provided with a potable water lot service outlet. The lot water service outlet riser shall be an approved rigid metallic material and not less than three-quarter ( 3/4) inch nominal pipe size. Each lot water service outlet shall be provided with an accessible water outlet designed for connecting a three-quarter ( 3/4) inch female swivel hose connection as defined in section 1308 of this chapter, in addition to the unit water connection.
(b) The lot water outlet shall be located within four (4) feet of the outside of the unit, or under the unit within eighteen (18) inches of the exterior wall of the unit.
(c) A separate water service shutoff valve shall be installed in each lot water service outlet at each lot.

Cal. Code Regs. Tit. 25, § 1274

1. Amendment filed 8-22-85; effective upon filing pursuant to Government Code Section 11346.2(d) (Register 85, No. 36).
2. Amendment of section heading, section and NOTE filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).

Note: Authority cited: Section 18300, Health and Safety Code. Reference: Sections 18630 and 18691, Health and Safety Code.

1. Amendment filed 8-22-85; effective upon filing pursuant to Government Code Section 11346.2(d) (Register 85, No. 36).
2. Amendment of section heading, section andNotefiled 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).