The Department has determined that cathodic protection to buried steel casing pipe is NOT a preferred method of corrosion control. If cathodic protection is required, it shall be provided by sacrificial magnesium anodes. The Department may waive cathodic protection to casing pipe if:
(a) The space between the casing and the carrier pipe has a full grout seal, unless otherwise precluded by federal regulations.(b) Full concrete encasement of the buried casing pipe designed for applicable wheel load requirements on the primary and secondary roads.(c) Mortar-coated steel pipe without cathodic protection may be used only in benign soil environments. A soil corrosivity analysis shall be submitted by the applicant.(d) Non-metallic casing pipe with concrete encasement is used.Cal. Code Regs. Tit. 23, § 615.2
1. New section filed 4-22-2015; operative 7-1-2015 (Register 2015, No. 17). Note: Authority cited: Section 12899.9, Water Code. Reference: Sections 12899, 12899.1(a), 12899.1(c) and 12899.2, Water Code.