Cal. Code Regs. tit. 23 § 130

Current through Register 2024 Notice Reg. No. 45, November 8, 2024
Section 130 - Patrol Roads and Access Ramps
(a) The following definitions apply to this section:
(1) Access Ramps - "Access Ramps" mean those ramps that provide access to the levee crown from adjacent property and roads.
(2) Patrol Roads - "Patrol Roads" means those roads that provide vehicular access along levee crowns and flood channels for inspection, maintenance, and flood fighting.
(b) Patrol roads must meet the following criteria:
(1) Patrol roads must be surfaced with a minimum of four (4) inches of compacted, class 2 aggregate base (Caltrans Spec. 26-1.02A, July 1992) which is incorporated by reference, or equivalent.
(2) Patrol road surfacing material must be compacted to a relative compaction of not less than ninety (90) percent per ASTM D1557-91, dated 1991, which is incorporated by reference with moisture content sufficient to obtain the required compaction.
(3) Compaction tests by a certified soils laboratory may be required to verify compaction.
(4) Paved patrol roads must meet the design requirements for paved bicycle trails, section 132.
(5) Levee crown surfacing must meet the following additional requirements:
(A) Where the crown width is less than sixteen (16) feet, the minimum surfacing width must be ten (10) feet with a smoothly tapered transition to the edge of the levee shoulder.
(B) Where the crown width is sixteen (16) feet or more, the minimum surfacing width must be twelve (12) feet with a two (2) foot-wide taper at each edge of the surfacing.
(C) The crown roadway must be sloped a minimum of two- (2) percent.
(6) Any patrol road which has been excavated or damaged must be restored to its original condition.
(c) Access ramps are of two common types, head-on or side approach, and must meet the following criteria:
(1) Access ramps must be constructed of approved imported material.
(2) The surfacing for all access ramps must be the same as for patrol roads. Subdivisions (b)(1), (b)(2) and (b)(3) of this section also apply to access ramps.
(3) Any excavation made in a levee section to key the ramp to the levee must be backfilled in four- (4) to six- (6) inch layers with approved material and compacted to a relative compaction of not less than ninety (90) percent per ASTM D1557-91, dated 1991, and above optimum moisture content.
(4) Compaction tests by a certified soils laboratory may be required to verify compaction.
(5) All access ramps must be constructed in such a manner so as to direct all surface drainage away from the levee section.
(6) Approved gates must be installed across access ramps at locations where vehicular access by the public is possible.
(7) Side approach ramps must be used on the waterside levee slope.
(8) Side approach ramps on the waterward slope of the levee must slope downstream.
(9) Typical plans for each type of approach ramp with restrictions and requirements are shown on Figures 8.08 and 8.09.

Cal. Code Regs. Tit. 23, § 130

1. New section and figures 8.08 and 8.09 filed 9-30-96; operative 10-30-96 (Register 96, No. 40).

Note: Authority cited: Section 8571, Water Code. Reference: Sections 8608 and 8710, Water Code.

1. New section and figures 8.08 and 8.09 filed 9-30-96; operative 10-30-96 (Register 96, No. 40).