Current through Register 2024 Notice Reg. No. 43, October 25, 2024
Section 66264.25 - Seismic and Precipitation Design Standards(a) Except as provided by sections 66264.175 and 66264.192, facilities subject to this chapter and all cover systems and drainage control systems required by this chapter shall be designed to function without failure when subjected to capacity, hydrostatic and hydrodynamic loads resulting from a 24-hour probable maximum precipitation storm.(b) The following shall be designed, constructed and maintained to withstand the maximum credible earthquake without the level of public health and environmental protection afforded by the original design being decreased: (1) all surface impoundments, waste piles, landfills and land treatment facilities subject to this chapter; and(2) all covers and cover systems required by this chapter and all containment and control features which will remain after closure at permanent hazardous waste disposal areas.Cal. Code Regs. Tit. 22, § 66264.25
1. New section filed 5-24-91; effective 7-1-91 (Register 91, No. 22). Note: Authority cited: Sections 208 and 25150, Health and Safety Code. Reference: Section 25150, Health and Safety Code.
1. New section filed 5-24-91; effective 7-1-91 (Register 91, No. 22).