Cal. Code Regs. tit. 21 § 1703.4

Current through Register 2024 Notice Reg. No. 44, November 1, 2024
Section 1703.4 - Reader-to-Transponder Trigger Pulse
(a) Trigger Pulse Definition.

The reader shall provide a wakeup trigger for the transponder. The trigger shall consist of a 33 microsecond long, RF pulse at the assigned carrier frequency that is modulated with a continuous string of ones. The trigger pulse shall be followed immediately by a delay (i.e., no RF transmission) of 100 microseconds in duration. The wakeup pulse is intended to signal a dormant transponder to fully activate itself.

(b) Trigger Pulse Field Strength.

The required horizontal component of field strength produced by the trigger pulse at the maximum downlink range (site dependent) of the reader shall be greater than 500 mV/m.

Cal. Code Regs. Tit. 21, § 1703.4

1. Renumbering of former section 1704.4 to new section 1703.4, including amendment of subsection (a), filed 11-28-2017; operative 1-1-2018 (Register 2017, No. 48).

Note: Authority cited: Section 27565, Streets and Highways Code. Reference: Sections 27564 and 27565, Streets and Highways Code.

1. Renumbering of former section 1704.4 to new section 1703.4, including amendment of subsection (a), filed 11-28-2017; operative 1/1/2018 (Register 2017, No. 48).