Table A-1
Commercial Refrigerator, Refrigerator-Freezer, and Freezer Test Methods
Appliance | Test Method |
Automatic commercial ice makers | 10 C.F.R. sections 431.133 and 431.134 |
Refrigerated bottled or canned beverage vending machines | 10 C.F.R. sections 431.293 and 431.294 |
Refrigerated buffet and preparation tables | ANSI/ASTM F2143-01 |
Other commercial refrigerators, refrigerator-freezers, and freezers, with doors | 10 C.F.R. sections 431.63 and 431.64 |
Other commercial refrigerators, refrigerator-freezers, and freezers, without doors | 10 C.F.R. sections 431.63 and 431.64 |
Walk-in coolers and walk-in freezers | 10 C.F.R. sections 431.303 and 431.304 |
EXCEPTION to Section 1604(a)(4) of this Article: Water dispensers equipped with an integral, automatic timer. Water dispensers equipped with an integral, automatic timer shall not be tested using Section 4)D, "Timer Usage," of the referenced test method.
Table B-1
Room Air Conditioner, Room Air-Conditioning Heat Pump, Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods
Appliance | Test Method |
Room air conditioners and room air-conditioning heat pumps | 10 C.F.R. section 430.23(f) (Appendix F to subpart B of part 430) |
Packaged terminal air conditioners and packaged terminal heat pumps | 10 C.F.R. sections 431.95 and 431.96 |
Table C-1
Central Air Conditioner Test Methods
Appliance | Test Method | ||
Computer Room Air Conditioners | |||
evaporatively cooled | ANSI/ASHRAE 127-2001 | ||
air-cooled, glycol-cooled, water-cooled | 10 C.F.R. sections 431.95 and 431.96 | ||
Other electric-powered unitary air-conditioners and electric-powered heat pumps | |||
air-cooled air conditioners and air-source heat pumps | |||
<65,000 Btu/hr, single-phase | 10 C.F.R. section 430.23(m) (Appendix M to subpart B of part 430) (for models manufactured before January 1, 2023, only) | ||
10 C.F.R. section 430.23(m) (Appendix M1 to subpart B of part 430) (for models manufactured on or after January 1, 2023, only) | |||
<65,000 Btu/hr, three-phase | 10 C.F.R. sections 431.95 and 431.96 | ||
>= 65,000 and < 760,000 Btu/hr evaporatively cooled air conditioners | 10 C.F.R. sections 431.95 and 431.96 | ||
< 240,000 Btu/hr | 10 C.F.R. sections 431.95 and 431.96 | ||
water-cooled air conditioners and water-source heat pumps | |||
< 240,000 Btu/hr | 10 C.F.R. sections 431.95 and 431.96 | ||
ground water-source heat pumps | ARI/ISO-13256-1:1998 | ||
ground-source closed-loop heat pumps | ARI/ISO-13256-1:1998 | ||
Variable Refrigerant Flow Multi-split Systems | 10 C.F.R. sections 431.95 and 431.96 | ||
Single Package Vertical Air Conditioners and Single Package Vertical Heat Pumps | 10 C.F.R. sections 431.95 and 431.96 | ||
Gas-fired air conditioners and gas-fired heat pumps | ANSI Z21.40.4-1996 as modified by CEC, Efficiency Calculation Method for Gas-Fired Heat Pumps as a New Compliance Option (1996) |
Table C-2 Air Filter Test Methods
Appliance Performance Criteria | Test Method |
Air Filter Pressure Drop | AHRI Standard 680 (I-P)-2017* or ANSI/ASHRAE Standard 52.2-2017 |
Minimum Efficiency Reporting Value (MERV) | ANSI/ASHRAE Standard 52.2-2017 |
Air Filter Particle Size Efficiency | AHRI Standard 680 (I-P)-2017* or ANSI/ASHRAE Standard 52.2-2017 |
Dust Holding Capacity | AHRI Standard 680 (I-P)-2017* or ANSI/ASHRAE Standard 52.2-2017 |
* MERV not reportable for models being tested to AHRI Standard 680 (I-P)-2017 only |
Q = C x dPn, where Q=airflow rate in cfm, dP=initial resistance pressure difference in inches water column, and C and n are the coefficients determined in the least squares fit.
Table D-3
Testing Requirements for the following Appliances
Appliance | Test Method |
Spot Air Conditioners | ANSI/ASHRAE 128-2001 |
Single-Duct and Dual-Duct Portable Air Conditioners | 10 C.F.R. section 430.23(dd) (Appendix CC to subpart B of part 430) |
Ceiling Fans 1 | 10 C.F.R. section 430.23(w) (Appendix U to subpart B of part 430) |
Ceiling Fan Light Kits | 10 C.F.R. section 430.23(x) (Appendix V to subpart B of part 430) |
Evaporative Coolers 2 | ANSI/ASHRAE 133-2008 for packaged direct evaporative coolers and packaged indirect/direct evaporative coolers; |
Whole House Fans | HVI-Publication 916 |
29 September 2015 HVI Airflow Test Procedure, as specified in section 5.2. | |
Use setups for whole house comfort ventilators. | |
Dehumidifiers | 10 C.F.R. section 430.23(z) (Appendix X to subpart B of part 430, active mode portion only) |
Portable Dehumidifiers and Whole-Home Dehumidifiers Manufactured On or After June 13, 2019 | 10 C.F.R. section 430.23(z) (Appendix X1 to subpart B of part 430) |
Residential Exhaust Fans | HVI-Publication 916 |
29 September 2015 HVI Airflow Test Procedure, as specified in section 5.2. | |
Residential Furnace Fans | 10 C.F.R. section 430.23(cc) (Appendix AA to subpart B of part 430) |
Commercial and Industrial Fans and Blowers | 10 C.F.R. section 431.174 (Appendix A to Subpart J of Part 431) 3 |
1 Very small-diameter ceiling fans are not required to be tested, unless those fans also meet the definition of "low-speed small-diameter ceiling fan" found in section 1602(d) of this Article.
2 Not including evaporative coolers whose fans or blowers are within the scope of the testing requirements for commercial and industrial fans and blowers.
3 Including but not limited to provisions on alternative efficiency determination method (AEDM) and additional testing requirements concerning selection of models to be tested if an AEDM is to be applied, in 10 C.F.R. sections 429.69 and 429.70.
Table E-1
Space Heating Product Test Methods
Appliance | Test Method | |||
Central furnaces | ||||
< 225,000 Btu/hr, single phase | 10 C.F.R. section 430.23(n) (Appendix N to subpart B of part 430) | |||
< 225,000 Btu/hr, three phase | 10 C.F.R. section 430.23(n) (Appendix N to subpart B of part 430) or 10 C.F.R. sections 431.75 and 431.76 (at manufacturer's option) | |||
>= 225,000 Btu/hr | 10 C.F.R. sections 431.75 and 431.76 | |||
Infrared gas space heaters | ||||
patio heaters | ASTM F2644-07 | |||
high-intensity infrared heaters | ANSI Z83.19-2001 | |||
low-intensity infrared heaters | ANSI Z83.20-2001 | |||
Gas duct furnaces | ANSI Z83.8-2002 | |||
Boilers | ||||
< 300,000 Btu/hr | 10 C.F.R. section 430.23(n) (Appendix N to subpart B of part 430) | |||
>= 300,000 Btu/hr | 10 C.F.R. sections 431.85 and 431.86 | |||
Vented home heating equipment | 10 C.F.R. section 430.23(o) (Appendix O to subpart B of part 430) |
The test methods for water heaters that are regulated under subpart G of 10 C.F.R. part 431 are found at 10 C.F.R. sections 431.105 and 431.106.
The test method for fossil fuel-fired pool heaters, electric resistance pool heaters, and electric heat pump pool heaters is 10 C.F.R. section 430.23(p) (Appendix P to subpart B of part 430).
Power Factor (%) = 100 x Input Power (W)/(Voltage(V) x Amps (A))
Three phase motors:
Power Factor (%) = 100 x Input Power (W)/(Voltage(V) x Amps(A) x 1.73)
where Voltage and Amps are the measured root mean square (rms) voltage and current.
The test methods for plumbing fixtures are:
Weighted ballast luminous efficacy = BLE100 x w100 + BLE80 x w80 + BLE50 x w50
Where the time values (w100, w80, w50) are taken from the appropriate table below:
Table J-1
Percentage Time of Operation Table
Time Variable | Measurements taken | |||
P80, P50 | P80, No P50 | No P80, P50 | No P80, No P50 | |
W100 | 0.2 | 0.35 | 0.45 | 1 |
W80 | 0.5 | 0.65 | 0 | 0 |
W50 | 0.3 | 0 | 0.55 | 0 |
Table K-1
Optional Test Methods for State-Regulated LED Lamps and LED State-Regulated Small Diameter Directional Lamps
Measurement | Test Procedure |
Flicker | Title 24, part 6, Joint Appendix 10 (2015), tested at both 100 percent and 20 percent output. Lamps with a percent amplitude modulation (percent flicker) less than 30 percent at frequencies less than 200 Hz shall report "yes" for "reduced flicker operation" described in section 1606 of this Article, otherwise report "no". |
Lumen Maintenance, Rated Life, and Survival Rate for Compliance with Title 24 Joint Appendix 8 and minimum dimming level | Title 24, part 6, Joint Appendix 8 (2015). |
Audible Noise | ENERGY STAR Recommended Practice -- Noise (2013) with the following modification: measurements shall be taken at 100 percent output as well as at 20 percent output if dimmable. |
Emergency Lighting. The test method for illuminated exit signs is 10 C.F.R. section 431.204(b).
Traffic Signal Modules. The test method for traffic signal modules for vehicle or pedestrian control is 10 C.F.R. section 431.224.
There is no test method for torchieres.
The test method for metal halide luminaires is ANSI C82.6-2005. Ballasts may be tested separately, outside the luminaire. A sample of at least five ballasts shall be tested for each lamp wattage for which the luminaire and ballasts are rated. The average of these tests shall be used for certification and compliance purposes.
Ballasts efficiency for High Intensity Discharge (HID) luminaire means the efficiency of a lamp and ballast combination expressed as a percentage and calculated by Efficiency = Pout / Pin, as measured. Pout is the measured operating lamp wattage and Pin is the measured operating input wattage.
The lamp, and the capacitor when it is provided, is to constitute a nominal system in accordance with ANSI C78.43-2004. Pin and Pout are to be measured after lamps have been stabilized according to Section 4.4 of ANSI C82.6-2005 using a wattmeter with accuracy specified in Section 4.5 of ANSI C82.6-2005 for ballasts with a frequency of 60 Hz and shall have a basic accuracy of ± 0.5 percent at the higher of (a.) three times the output operating frequency of the ballast, or (b.) 2 kHz for ballast with a frequency greater than 60 Hz.
The test method for under-cabinet luminaires is 10 C.F.R. 430.23(q) (Appendix Q to subpart B of part 430 (2015)).
The test method for dishwashers is 10 C.F.R. section 430.23(c) (Appendix C1 to subpart B of part 430).
The test methods for clothes dryers are 10 C.F.R. section 430.23(d) (Appendix D1 or Appendix D2 to subpart B of part 430). Manufacturers must use a single appendix for all representations, including certifications of compliance, and may not use appendix D1 for certain representations and appendix D2 for other representations.
The test methods for cooking products and food service equipment are shown in Table R-1.
Table R-1
Cooking Product and Food Service Equipment Test Methods
Appliance | Test Method |
Microwave ovens | 10 C.F.R. section 430.23(i) (Appendix I to subpart B of part 430) |
Conventional cooktops and combined cooking products | 10 C.F.R. section 430.23(i) (Appendix I1 to subpart B of part 430) |
Commercial hot food holding cabinets | ANSI/ASTM F2140-01 (Test for idle energy rate-dry test) and US EPA's Energy Star Guidelines, "Measuring Interior Volume" (Test for interior volume) |
Commercial convection ovens | ANSI/ASTM F1496-99 (Test for energy input rate and idle energy consumption only) |
Commercial range tops | ANSI/ASTM F1521-96 (Test for cooking energy efficiency only) |
The test method for distribution transformers is 10 C.F.R. section 431.193 (Appendix A of subpart K).
Table V-1
Interface Types and Scores for Expandability Score Calculation
Interface Type | Interface Score |
USB 2.0 or less | 5 |
USB 3.0 or 3.1 Gen 1 | 10 |
USB 3.1 Gen 2 | 15 |
USB ports or Thunderbolt 3.0 or greater that can provide 100 or more watts of power | 100 |
USB ports or Thunderbolt 3.0 or greater that can provide from 60 or more to less than 100 watts of power | 60 |
USB ports or Thunderbolt 3.0 or greater that can provide from 30 or more to less than 60 watts of power | 30 |
Thunderbolt 3.0 or greater or USB ports that are not otherwise addressed in Table V-1 and that cannot provide 30 or more watts of power | 20 |
Unconnected USB 2.0 motherboard header | 10 per header |
Unconnected USB 3.0 or 3.1 Gen 1 motherboard header | 20 per header |
PCI slot other than PCIe x16 (only count mechanical slots) | 25 |
PCIe x16 or higher (only count mechanical slots) | 75 |
Thunderbolt 2.0 or less | 20 |
M.2 (except key M) | 10 |
IDE, SATA, eSATA | 15 |
M.2 key M, SATA express, U.2 | 25 |
Integrated liquid cooling | 50 |
Either: | 100 |
1) CPU and motherboard support for 4 or more channels of system memory and at least 8 GB of installed and compatible system memory; or | |
2) At least 8 GB of system memory installed on a 256 bit or greater memory interface. |
The following documents are incorporated by reference in section 1604.
Number | Title |
CALIFORNIA ENERGY COMMISSION TEST METHODS | |
CEC/Gas-Fired Heat Pumps | Efficiency Calculation Method for Gas-Fired Heat Pumps as a Exceptional Method (1996) New Compliance Option (1996) |
California Title 24, part 6, Joint Appendix 8 JA-8 -- 2015 | Qualification Requirements for High Efficacy Light Sources |
California Title 24, part 6, Joint Appendix 10 JA-10 -- 2015 | Test Method for Measuring Flicker of Lighting Systems and Reporting Requirements |
Copies available from: | CALIFORNIA ENERGY COMMISSION |
ENERGY HOTLINE | |
715 P STREET, MS-25 | |
SACRAMENTO, CALIFORNIA 95814 | |
PHONE: (916) 654-5106 | |
FAX: (916) 654-4304 |
FEDERAL TEST METHODS
C.F.R., Title 10, sections 429.12, 429.16, 429.56, 429.63, 429.69, and 429.70
C.F.R., Title 10, section 430.23, and 10 C.F.R. Appendixes A, B, C1, D1, D2, E, F, H, I, I1, J, J2, M, M1, N, O, P, Q, R, S, T, U, V, W, X, S 1, Y, Y1, Z, AA, BB, CC, and DD of subpart B of part 430
C.F.R., Title 10, sections 431.15, 431.16, 431.17, 431.18, 431.19, 431.20, and 431.21
C.F.R., Title 10, sections 431.63 and 431.64
C.F.R., Title 10, sections 431.75 and 431.76
C.F.R., Title 10, sections 431.85 and 431.86
C.F.R., Title 10, sections 431.95 and 431.96
C.F.R., Title 10, sections 431.105 and 431.106
C.F.R., Title 10, sections 431.133 and 431.134
C.F.R., Title 10, section 431.154
C.F.R., Title 10, section 431.174, Appendix A to Subpart J of 10 C.F.R., § 431
C.F.R., Title 10, section 431.193
C.F.R., Title 10, section 431.204(b)
C.F.R., Title 10, section 431.224
C.F.R., Title 10, sections 431.263 and 431.264
C.F.R., Title 10, sections 431.293 and 431.294
C.F.R., Title 10, sections 431.303 and 431.304
C.F.R., Title 10, section 431.344, Appendix A to Subpart T of 10 C.F.R., § 431
C.F.R., Title 10, sections 431.443, 431.444, and 431.445
C.F.R., Title 10, section 431.464(a) Appendix A to Subpart Y of 10 C.F.R., § 431
C.F.R., Title 10, section 431.464(b), Appendix C to Subpart Y of 10 C.F.R., § 431
C.F.R., Title 10, section 431 subpart G
Number | Title |
Copies available from: | SUPERINTENDENT OF DOCUMENTS |
U.S. GOVERNMENT PRINTING OFFICE | |
WASHINGTON, DC 20402 | |
www.ecfr.gov | |
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (EPA) | |
ENERGY STAR® Program | |
Requirements for | |
Bottled Water Coolers (2004) | |
ENERGY STAR® Program Requirements for Computers, subparts Eligibility Criteria | |
Version 6.1 (Rev. March-2016) and Final | |
Test Method (Rev. March-2016) | |
ENERGY STAR® Program Requirements f for Displays, subpart Final Test Method | |
(Rev. Sep-2015) | |
EPA "Test Method for Calculating the Energy Efficiency of Single-Voltage External AC-DC and AC-AC Power Supplies" | |
(August 11, 2004) | |
Energy Star Guidelines, "Measuring Interior Volume" (Test for measuring interior volume of commercial hot food holding cabinets) | |
ENERGY STAR Recommended Practice -- Noise (2013) | EPA ENERGY STAR® Program Requirements Product Specification for Lamps (Light Bulbs) |
Version 1.1 (August 2014). | |
Copies available from: | US EPA |
CLIMATE PROTECTION PARTNERSHIP | |
ENERGY STAR PROGRAMS HOTLINE & | |
DISTRIBUTION | |
(MS-6202J) | |
1200 PENNSYLVANIA AVE NW | |
WASHINGTON, DC 20460 | |
www.energystar.gov | |
Appendix B of the WaterSense® | |
Specification for | |
Spray Sprinkler Bodies | |
Version 1.0 (Dated September 21, 2017) | |
Copies available from: | WATERSENSE® |
U.S. ENVIRONMENTAL PROTECTION AGENCY | |
OFFICE OF WASTEWATER MANAGEMENT | |
(4204M) | |
1200 PENNSYLVANIA AVENUE, N.W. | |
WASHINGTON, D.C. 20460 | |
HTTPS://WWW.EPA.GOV/WATERSENSE | |
AIR-CONDITIONING, HEATING, AND REFRIGERATION INSTITUTE (AHRI) | |
AHRI Standard 680 (I-P)-2017 | 2017 Standard for Performance Rating of Residential Air Filter Equipment |
Copies available from: | AIR-CONDITIONING, HEATING, AND REFRIGERATION INSTITUTE (AHRI) |
2111 WILSON BLVD, SUITE 500 | |
ARLINGTON, VA 22201 | |
PHONE: (703) 524-8800 | |
FAX: (703) 562-1942 | |
http://www.ahrinet.org/ | |
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) | |
ANSI/ASHRAE Standard 52.2-2017 | Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size |
ANSI C78.43-2004 | American National Standards for Electric |
Lamps -- Single-Ended Metal Halide Lamps | |
ANSI C82.6-2005 | Ballasts for High Intensity Discharge |
Lamps -- Method of Measurement | |
ANSI Z21.10.3-1998 | Standard for Gas Water Heaters, Volume III, Storage Water Heaters with Input Ratings |
Above 75,000 Btu per hour, Circulating and Instantaneous | |
ANSI Z21.40.4-1996 | Performance Testing and Rating of Gas-Fired Air-Conditioning and Heat Pump Appliances |
ANSI Z83.8-2002 | Standard for Gas Unit Heaters and Gas-Fired Duct Furnaces |
ANSI Z83.19-2001 | Standard for Gas-Fired High-Intensity Infrared Heaters |
ANSI Z83.20-2001 | Standard for Gas-Fired Low-Intensity Infrared Heaters |
ANSI/AHRI 550-590 (I-P) 2011 | Performance Rating of Water-Chilling and Heat Pump Water-Heating Packages Using the Vapor Compression Cycle |
Copies available from: | AMERICAN NATIONAL STANDARDS INSTITUTE |
1819 L STREET, NW, 6TH FLOOR | |
WASHINGTON DC 20036 | |
www.ansi.org | |
PHONE: (202) 293-8020 | |
FAX: (202) 293-9287 | |
AMERICAN SOCIETY FOR MECHANICAL ENGINEERS (ASME) | |
ASME A112.19.2/CSA B45.1-2013 | Ceramic Plumbing Fixtures |
ASME A112.18.1-2012 & 2018/CSA B125.1-2012 & 2018 | Plumbing Supply Fittings |
Copies available from: | ASME HEADQUARTERS |
TWO PARK AVENUE | |
NEW YORK, NY 10016-5990 | |
www.asme.org | |
PHONE: 800-843-2763 (U.S./CANADA) | |
001-800-843-2763 (MEXICO) | |
973-882-1170 (OUTSIDE NORTH AMERICA) | |
EMAIL: CustomerCare@asme.org | |
AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS (ASHRAE) | |
ANSI/ASHRAE 118.2-1993 | Method of Testing for Rating Residential Water Heaters |
ANSI/ASHRAE 124-2007 | Method of Testing for Rating Combination |
Space-Heating and Water-Heating | |
Appliances | |
ANSI/ASHRAE 127-2001 | Method of Testing for Rating Computer and |
Data Processing Room Unitary | |
Air-Conditioners | |
ANSI/ASHRAE 128-2001 | Method of Rating Spot Unitary Air Conditioners |
ANSI/ASHRAE 133-2008 | Method of Testing Direct Evaporative Air Coolers |
ANSI/ASHRAE 143-2007 | Method of Test for Rating Indirect Evaporative Coolers |
ANSI/ASHRAE 146-1998 | Method of Testing and Rating Pool Heaters |
Copies available from: | AMERICAN SOCIETY OF HEATING, |
REFRIGERATING AND AIR-CONDITIONING | |
ENGINEERS | |
1791 TULLIE CIRCLE N.E. | |
ATLANTA, GA 30329 | |
WWW.ASHRAE.ORG | |
PHONE: (800) 527-4723 (U.S./CANADA) OR | |
(404) 636-8400 | |
FAX: (404) 321-5478 | |
ASTM INTERNATIONAL | |
ANSI/ASTM F1496-99 | Standard Test Method for Performance of Convection Ovens |
ANSI/ASTM F1521-96 | Standard Test Methods for Performance of Range Tops |
ANSI/ASTM F2140-01 | Standard Test Method for the Performance of Hot Food |
Holding | Cabinets |
ANSI/ASTM F2143-01 | Standard Test Method for the Performance of Refrigerated |
Buffet and | Preparation Tables |
ASTM F2644-07 | Standard Test Method for Performance of Commercial Patio Heaters |
Copies available from: | ASTM |
100 Barr Harbor Drive | |
West Conshohocken, PA 19428-2959 | |
www.astm.org | |
Phone: 1-877-909-2786 | |
CANADIAN STANDARDS ASSOCIATION (CSA) | |
CSA B45.1-2013 | Ceramic Plumbing Fixtures |
CSA C747-09 (reaffirmed 2014) | Energy efficiency test methods for small motors |
Copies available from: | CANADIAN STANDARDS ASSOCIATION |
178 REXDALE BLVD. | |
TORONTO, ONTARIO, CANADA, M9W 1R3 | |
PHONE: (416) 747-4044 | |
http:/shop.csa.ca/ | |
ECOS CONSULTING | |
Energy Efficiency Battery Charger System Test Procedure Version 2.2 dated November 12, 2008 | |
Copies available from: | ECOS CONSULTING |
801 FLORIDA ROAD, # 11 | |
DURANGO, CO 81301 | |
HTTP://WWW.EFFICIENTPRODUCTS.ORG/ | |
PHONE: (970) 259-6801 | |
FAX: (970) 259-8585 | |
ECOVA | |
Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies Revision 6.7 (March 1, 2014) | |
Copies available from: | PLUG LOAD SOLUTIONS BY ECOVA |
www.plugloadsolutions.com | |
PHONE: (971) 201-4180 | |
HOME VENTILATING INSTITUTE (HVI) | |
HVI-Publication 916 | 29 September 2015 HVI |
Air-flow Test Procedure | |
Copies available from: | HOME VENTILATING INSTITUTE |
1000 N. RAND RD., SUITE 214 | |
WAUCONDA, IL 60084 | |
WWW.HVI.ORG | |
PHONE: (847) 526-2010 | |
FAX: (847) 526-3993 | |
ILLUMINATING ENGINEERING SOCIETY (IES) | |
IES LM-84-14 | Measuring Luminous Flux and Color Maintenance of LED Lamps, Light Engines, and Luminaires |
IES TM-28 (2014) | Projecting Long-Term Luminous Flux Maintenance of LED Lamps and Luminaires |
Copies available from: | ILLUMINATING ENGINEERING SOCIETY |
120 WALL STREET, 17TH FLOOR | |
NEW YORK, NY 10005-4001 | |
WWW.IES.ORG | |
PHONE: (212) 248-5000 | |
FAX: (212) 248-5617/8 | |
INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) | |
IEC 62087 (2002)(E) | Methods of Measurement for the Power Consumption of Audio, Video, and Related Equipment. |
IEC 62087:2008(E), Edition 2.0 | Methods of Measurement for the Power Consumption of Audio, Video, and Related Equipment |
IEC 62087:2011 | Methods of measurement for the power consumption of audio, video and related equipment |
IEC 62301:2011 | Household electrical appliances -- Measurement of standby power |
IEC 62623:2012 | Desktop and notebook computers -- Measurement of energy consumption |
Copies available from: | IEC CENTRAL OFFICE |
3, RUE DE VAREMBÉ | |
P.O. BOX 131 | |
CH - 1211 GENEVA 20 | |
SWITZERLAND | |
PHONE: +41 22 919 02 11 | |
INTERNATIONAL ORGANIZATION FOR STANDARDS (ISO) | |
ISO 13256-1-1998 | Water-source heat pumps-Testing and rating for performance-part 1: Water-to-air and brine-to-air heat pumps |
Copies available from: | ISO CENTRAL SECRETARIAT |
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION (ISO) | |
1, RUE DE VAREMBÉ, CASE POSTALE 56 | |
CH-1211 GENEVA 20, SWITZERLAND | |
WWW.ISO.ORG | |
PHONE: +41 22 749 01 11 | |
FAX: +41 22 733 34 30 | |
INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) | |
IEEE 114-2001 | Standard Test Procedures for Single-Phase Induction Motors |
IEEE 802.3-2015 | IEEE Standard for Ethernet |
IEEE 802.11-2012 | IEEE Standard for Information technology -- Telecommunications and information exchange between systems |
Local and metropolitan area networks -- Specific requirements | |
Part 11: Wireless LAN Medium Access | |
Control (MAC) and Physical Layer (PHY) | |
Specifications | |
Copies available from: | INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS |
PUBLICATIONS OFFICE | |
10662 LOS VAQUEROS CIRCLE | |
PO BOX 3014 | |
LOS ALAMITOS, CA 90720-1264 | |
WWW.IEEE.ORG | |
PHONE: (714) 821-8380 | |
FAX: (714) 821-4010 | |
THE POOL AND HOT TUB ALLIANCE | |
ANSI/APSP/ICC-14 2019 | American National Standard for Portable Electric Spa Energy Efficiency |
Copies available from: | Pool & Hot Tube Alliance |
2111 Eisenhower Avenue, Suite 500 | |
Alexandria, VA 22314-4695 | |
PHTA.org | |
Phone: (703) 838-0083 | |
UNIFIED EXTENSIBLE FIRMWARE INTERFACE FORUM | |
Advanced Configuration and Power Interface Specification Revision 5.0 (December 6, 2011) and Advanced Configuration and Power Interface Specification Revision 5.0 Errata A (November 13, 2013) | Advanced Configuration and Power Interface Specification |
Copies available from: | UEFI FORUM ADMINISTRATION |
3855 SW 153RD DRIVE | |
BEAVERTON, OR 97003 USA | |
www.uefi.org | |
PHONE: +1 503-619-0864 | |
FAX: +1 503-644-6708 |
Cal. Code Regs. Tit. 20, § 1604
Note: Authority cited: Sections 25213, 25218(e), 25401.9, 25402(a)- 25402(c) and 25960, Public Resources Code; and Sections 16, 26 and 30, Governor's Exec. Order No. B-29-15 (April 1, 2015). Reference: Sections 25216.5(d), 25401.9, 25402(a)- 25402(c) and 25960, Public Resources Code; and Section 16, Governor's Exec. Order No. B-29-15 (April 1, 2015).
2. New subsection (g) filed 10-1-82; designated effective 6-2-83 (Register 82, No. 40).
3. Amendment of Table C-2 filed 1-3-83; effective thirtieth day thereafter (Register 83, No. 2).
4. Amendment of subsection (f) filed 1-14-83; effective thirtieth day thereafter (Register 83, No. 3).
5. Amendment of subsection (d)(2) filed 1-20-83; effective thirtieth day thereafter (Register 83, No. 7).
6. Editorial correction of subsections (a) and (b) and Tables A and B (Register 83, No. 18).
7. Amendment of subsection (a) filed 3-26-85; effective thirtieth day thereafter (Register 85, No. 13).
8. Amendment of subsection (c) filed 4-10-85; effective thirtieth day thereafter (Register 85, No. 18).
9. Amendment filed 5-22-85; effective thirtieth day thereafter (Register 85, No. 21).
10. Amendment of subsection (c) filed 4-10-85; effective thirtieth day thereafter (Register 85, No. 21).
11. Amendment filed 7-20-87; operative 8-19-87 (Register 85, No. 30).
12. Amendment filed 8-29-88; operative 9-28-88 (Register 88, No. 37).
13. Amendment of subsections (a)-(c), new subsection (d) reserved, and renumbering and amendment of former subsections (d)-(g) to subsections (e)-(h) filed 6-5-90; operative 7-5-90 (Register 90, No. 31).
14. Amendment filed 11-6-91; operative 12-6-91 (Register 92, No. 9).
15. Amendment of Table F-2 filed 1-16-92; operative 1-16-92 pursuant to Government Code section 11346.2(d) (Register 92, No. 15).
16. Amendment of subsection (f)(2) and Table F-2, new Table F-3, amendment of subsection (f)(3), renumbering and amendment of Table F-3 to Table F-4, and amendment of subsection (f)(4) and renumbering of Table F-4 to F-5 filed 7-23-92; operative 8-24-92 (Register 92, No. 35).
17. Repealer and new section filed 10-28-2002; operative 11-27-2002 (Register 2002, No. 44).
18. Amendment of subsection (f)(5)(E) filed 4-1-2003 as an emergency; operative 4-1-2003 (Register 2003, No. 14). A Certificate of Compliance must be transmitted to OAL by 7-30-2003 or emergency language will be repealed by operation of law on the following day.
19. Certificate of Compliance as to 4-1-2003 order transmitted to OAL 7-8-2003 and filed 8-19-2003 (Register 2003, No. 34).
20. Amendment of subsection (p) and list of incorporated documents filed 7-29-2004; operative 8-28-2004 (Register 2004, No. 31).
21. Amendment filed 3-16-2005; operative 4-15-2005 (Register 2005, No. 11).
22. Amendment of Table A-1, subsection (a)(4), Tables B-1, D, E-1 and F-1, subsections (h)(1), (j)-(k), (n)(3) and (o), Table P-1, subsection (q), Table R, subsections (s) and (u)(1) and federal test methods filed 12-30-2005; operative 1-1-2006 pursuant to Government Code section 11343.4 (Register 2005, No. 52).
23. Amendment of subsection (u)(1) and Note filed 6-22-2006; operative 6-22-2006 pursuant to Government Code section 11343.4 (Register 2006, No. 25).
24. Amendment of Table D and subsections (f)(5)(F), (k) and (n)(2) and amendment of list of incorporated documents filed 12-14-2006; operative 12-14-2006 pursuant to Government Code section 11343.4 (Register 2006, No. 50).
25. Amendment of subsection (c) - Table C-1, subsection (s) and list of incorporated documents filed 8-22-2007; operative 9-17-2007 pursuant to Government Code section 11343.4 (Register 2007, No. 34).
26. Amendment filed 7-10-2009; operative 8-9-2009 (Register 2009, No. 28).
27. Redesignation and amendment of former subsection (k) as new subsection (k)(1), new subsections (k)(2)-(3) and (n)(4) and amendment of list of incorporated standards and Note filed 7-10-2009; operative 8-9-2009 (Register 2009, No. 28).
28. Amendment of subsection (v), including redesignation and amendment of portion of former subsection (v) as new subsection (v)(1), new subsections (v)(2)-(v)(3)(D)6. and amendment of list of incorporated standards filed 9-1-2010; operative 1-1-2011 (Register 2010, No. 36).
29. Amendment of subsection (l), new subsections (l)(1)-(2), amendment of subsections (w)(1) and (w)(2), new subsections (w)(1)(A)-(D) and (w)(2)(A)-(B) and amendment of list of incorporated documents to update revision date of 10 CFR 430.23 filed 10-26-2012; operative 1-1-2013 (Register 2012, No. 43).
30. Amendment filed 4-22-2014; operative 7-1-2014 (Register 2014, No. 17).
31. Amendment of subsection (i), new subsections (i)(1)-(2), amendment of list of incorporated documents and amendment of Note filed with the Secretary of State by the Office of Administrative Law on 5-15-2015. Submitted to OAL for printing only pursuant to Governor's Executive Order No. B-29-15 (4-1-2015); operative 5/15/2015 (Register 2015, No. 20).
32. New subsections (h)(2)-(h)(2)(C), subsection renumbering, amendment of subsection (i)(1), new subsection (i)(2), subsection renumbering and amendment of list of incorporated documents filed 8-20-2015; operative 8/20/2015 pursuant to Governor's Executive Order No. B-29-15, directive 30 (4-1-2015) (Register 2015, No. 34).
33. New subsections (h)(5)-(6) and amendment of subsection (i)(3) filed 2-10-2016; operative 2/10/2016. Exempt from OAL review pursuant to Governor's Executive Order B-29-15, issued 4-1-2015 (Register 2016, No. 7).
34. Amendment of subsections (a) and (c), new subsections (c)(4)-(5), amendment of subsections (d), (f)(1) and (j), new subsections (j)(3)-(j)(3)(D) and amendment of subsections (o), (p) and (w)(2)(B) filed 6-30-2016; operative 7/1/2016 pursuant to Government Code section 11343.4(b)(3) (Register 2016, No. 27).
35. Amendment of subsections (k)(2) and (k)(4), including new table K-1, and list of documents incorporated by reference filed 11-1-2016; operative 1/1/2017 (Register 2016, No. 45).
36. Amendment of subsections (v) and (v)(2)-(3), new subsections (v)(4)-(v)(5)(I) and amendment of list of incorporated documents filed 8-22-2017; operative 10/1/2017 (Register 2017, No. 34).
37. Change without regulatory effect amending Table D-1 and list of incorporated documents filed 9-11-2017 pursuant to section 100, title 1, California Code of Regulations (Register 2017, No. 37).
38. Adoption and amendment of subsections within subsection (g)(2) and amendment of list of incorporated documents filed 7-19-2018; operative 10/1/2018 (Register 2018, No. 29).
39. Amendment filed 9-26-2018; operative 10-1-2018 pursuant to Government Code section 11343.4(b)(3) (Register 2018, No. 39).
40. Editorial correction of subsection (a)(4) (Register 2018, No. 45).
41. Change without regulatory effect amending footnote to Table K-1, amending Table R-1 and amending list of documents incorporated by reference filed 3-18-2019 pursuant to section 100, title 1, California Code of Regulations (Register 2019, No. 12).
42. Amendment of subsection (s)(3) and list of documents incorporated by reference filed 6-10-2019; operative 6/10/2019 pursuant to Government Code section 11343.4(b)(3) (Register 2019, No. 24).
43. New subsections (x)-(x)(1)(A), amendment of list of documents incorporated by reference and amendment of Note filed 10-7-2019; operative 10/1/2020 pursuant to Government Code section 11343.4(b)(2) and Public Resources Code section 25402(c)(1) (Register 2019, No. 41).
44. Amendment of subsection (k)(1), repealer of subsection (k)(2), subsection renumbering, amendment of newly designated subsections (k)(2)-(3), new subsection (k)(4), amendment of Table K-1 and subsection (k)(5) and amendment of list of documents incorporated by reference filed 12-24-2019; operative 1/1/2020 pursuant to Government Code section 11343.4(b)(3) (Register 2019, No. 52).
45. Amendment of subsection (g), repealer of subsections (g)(3)-(g)(3)(D), subsection numbering, amendment of newly designated subsection (g)(3), new subsections (g)(3)(A)-(g)(3)(C)2. and amendment of list of documents incorporated by reference filed 9-21-2020; operative 1/1/2021 (Register 2020, No. 39). Filing deadline specified in Government Code section 11349.3(a) extended 60 calendar days pursuant to Executive Order N-40-20 and an additional 60 calendar days pursuant to Executive Order N-66-20.
46. New subsections (v)(4)(J)-(v)(4)(K)4. filed 2-3-2021; operative 12/9/2021 pursuant to Government Code section 11343.4(b)(1) and Public Resources Code section 25402(c)(1) (Register 2021, No. 6).
47. Amendment of subsections (a)4), (g)(2)(C), (k)(4) and (l), repealer of subsections (l)(1)-(2), amendment of subsections (n)(4)(A) and (w)(2)(D) and amendment of list of documents incorporated by reference filed 3-16-2021; operative 3-16-2021 pursuant to Government Code section 11343.4(b)(3) (Register 2021, No. 12). (Filing deadline specified in Government Code section 11349.3(a) extended 60 calendar days pursuant to Executive Order N-40-20.)
48. Change without regulatory effect amending subsections (g)(2)(B)3.-4. and (g)(2)(C) and repealer of subsection (g)(4) filed 7-12-2021 pursuant to section 100, title 1, California Code of Regulations (Register 2021, No. 29).
49. Repealer of subsections (g)(2)(A)-(B), new subsection (g)(2)(A), redesignation and amendment of former subsection (g)(2)(C) as subsection (g)(2)(B) and amendment of list of documents incorporated by reference filed 9-8-2021; operative 1/1/2022 (Register 2021, No. 37).
50. Editorial correction removing duplicate subsection (v)(4) (Register 2022, No. 43).
51. Amendment of subsection (d), redesignation of portion of former subsection (d) as subsection (d)(1), amendment of Table D-3 heading, new subsections (d)(2)-(d)(2)(A), and amendment of list of documents incorporated by reference filed 1-17-2023; operative 11-16-2023 (Register 2023, No. 3).
52. Amendment of subsection (c)(3), including new subsections (c)(3)(A) and (c)(3)(B) and amendment of Table C-2, and amendment of list of documents incorporated by reference filed 4-7-2023; operative 7/1/2024 (Register 2023, No. 14).
53. Repealer of subsections (n)(4)-(n)(4)(B) and amendment of list of documents incorporated by reference filed 4-25-2023; operative 4-25-2023 pursuant to Government Code section 11343.4(b)(3) (Register 2023, No. 17).
54. Amendment filed 7-18-2024; operative 7/18/2024 pursuant to Government Code section 11343.4(b)(3) (Register 2024, No. 29).