Cal. Code Regs. tit. 17 § 95471

Current through Register 2024 Notice Reg. No. 36, September 6, 2024
Section 95471 - Test Methods and Procedures
(a)Hydrocarbon Detector Specifications: Any instrument used for the measurement of methane must be a gas detector or other equivalent instrument approved by the Executive Officer that meets the calibration, specifications, and performance criteria of EPA Reference Method 21, Determination of Volatile Organic Compound Leaks, 40 CFR Part 60 , Appendix A (as last amended 65 Fed.Reg. 61744 (October 17, 2000)), which is incorporated by reference herein, except for the following:
(1) "Methane" replaces all references to volatile organic compounds (VOC).
(2) The calibration gas shall be methane.
(b)Determination of Landfill Gas Heat Input Capacity: The landfill gas heat input capacity must be determined pursuant to sections 95471(b)(1), 95471(b)(2), or 95471(b)(3), as applicable:
(1)MSW Landfills without Carbon Adsorption or Passive Venting Systems: The heat input capacity must be calculated using the procedure as specified in Appendix I. The Executive Officer may request additional information as may be necessary to verify the heat input capacity from the MSW landfill. Site-specific data may be substituted when available.
(2)MSW Landfills with Carbon Adsorption Systems: The landfill gas heat capacity must be determined by measuring the actual total landfill gas flow rate, in standard cubic feet per minute (scfm), using a flow meter or other flow measuring device such as a standard pitot tube and methane concentration (percent by volume) using a hydrocarbon detector meeting the requirements of 95471(a). The total landfill gas flow rate must be multiplied by the methane concentration and then multiplied by the gross heating value (GHV) of methane of 1,012 Btu/scf to determine the landfill gas heat input capacity.
(3)MSW Landfills with Passive Venting Systems: The landfill gas heat input capacity must be determined pursuant to both of the following and is the higher of those determined values:
(A) Section 95471(b)(1); and
(B) The owner or operator must measure actual landfill gas flow rates (in units of scfm) by using a flow measuring device such as a standard pitot tube and methane concentration (percent by volume) using a hydrocarbon detector meeting the requirements of 95471(a) from each venting pipe that is within the waste mass. Each gas flow rate must then be multiplied by its corresponding methane concentration to obtain the individual methane flow rate. The individual methane flow rates must be added together and then multiplied by the GHV of methane of 1,012 Btu/scf to determine the landfill gas heat input capacity.
(c)Surface Emissions Monitoring Procedures: The owner or operator must measure the landfill surface concentration of methane using a hydrocarbon detector meeting the requirements of section 95471(a). The landfill surface must be inspected using the following procedures:
(1)Monitoring Area: The entire landfill surface must be divided into individually identified 50,000 square foot grids. The grids must be used for both instantaneous and integrated surface emissions monitoring.
(A) Testing must be performed by holding the hydrocarbon detector's probe within 3 inches of the landfill surface while traversing the grid.
(B) The walking pattern must be no more than a 25-foot spacing interval and must traverse each monitoring grid.
1. If the owner or operator has no exceedances of the limits specified in section 95465 after any four consecutive quarterly monitoring periods, the walking pattern spacing may be increased to 100-foot intervals. The owner or operator must return to a 25-foot spacing interval upon any exceedances of the limits specified in section 95465 that cannot be remediated within 10 calendar days or upon any exceedances detected during a compliance inspection.
2. If an owner or operator of a MSW landfill can demonstrate that in the past three years before the effective date of this subarticle that there were no measured exceedances of the limit specified in section 95465(a)(1) by annual or quarterly monitoring, the owner or operator may increase the walking pattern spacing to 100-foot intervals. The owner or operator must return to a 25-foot spacing interval upon any exceedances of the limits specified in section 95465 that cannot be remediated within 10 calendar days or upon any exceedances detected during a compliance inspection.
(C) Surface testing must be terminated when the average wind speed exceeds five miles per hour or the instantaneous wind speed exceeds 10 miles per hour. The Executive Officer may approve alternatives to this wind speed surface testing termination for MSW landfills consistently having measured winds in excess of these specified limits. Average wind speed must be determined on a 15-minute average using an on-site anemometer with a continuous recorder for the entire duration of the monitoring event.
(D) Surface emissions testing must be conducted only when there has been no measurable precipitation in the preceding 72 hours.
(2)Instantaneous Surface Emissions Monitoring Procedures.
(A) The owner or operator must record any instantaneous surface readings of methane 200 ppmv or greater, other than non-repeatable, momentary readings.
(B) Surface areas of the MSW landfill that exceed a methane concentration limit of 500 ppmv must be marked and remediated pursuant to section 95469(a)(1).
(C) The wind speed must be recorded during the sampling period.
(D) The landfill surface areas with cover penetrations, distressed vegetation, cracks or seeps must also be inspected visually and with a hydrocarbon detector.
(3)Integrated Surface Emissions Monitoring Procedures.
(A) Integrated surface readings must be recorded and then averaged for each grid.
(B) Individual monitoring grids that exceed an average methane concentration of 25 ppmv must be identified and remediated pursuant to section 95469(a)(2).
(C) The wind speed must be recorded during the sampling period.
(d)Gas Collection and Control System Leak Inspection Procedures. Leaks must be measured using a hydrocarbon detector meeting the requirements of 95471(a).
(e)Determination of Expected Gas Generation Flow Rate. The expected gas generation flow rate must be determined as prescribed in the 2006 Intergovernmental Panel on Climate Change (IPCC) Guidelines for National Greenhouse Gas Inventories, Chapter 3, which is incorporated by reference herein, using a recovery rate of 75 percent.
(f)Control Device Destruction Efficiency Determination. The following methods of analysis must be used to determine the efficiency of the control device in reducing methane:
(1)Enclosed Combustors: One of the following test methods, all of which are incorporated by reference herein (and all as promulgated in 40 CFR, Part 60 , Appendix A, as last amended 65 Fed.Reg. 61744 (October 17, 2000) at the pages cited below must be used to determine the efficiency of the control device in reducing methane by at least 99 percent, or in reducing the outlet methane concentration for lean burn engines to less than 3,000 ppmv, dry basis, corrected to 15 percent oxygen:

U.S. EPA Reference Method 18, Measurement of Gaseous Organic Compound Emissions By Gas Chromatography (65 Fed.Reg. at 62007);

U.S. EPA Reference Method 25, Determination of Total Gaseous Nonmethane Organic Emissions as Carbon (65 Fed.Reg. at 62044);

U.S. EPA Reference Method 25A, Determination of Total Gaseous Organic Concentration Using a Flame Ionization Analyzer (65 Fed.Reg. at 62062); or

U.S. EPA Reference Method 25C, Determination of Nonmethane Organic Compounds in Landfill Gases (65 Fed.Reg. at 62066).

The following equation must be used to calculate destruction efficiency:

Click here to view image

(2)Open Flares: Open flares must meet the requirements of 40 CFR § 60.18 (as last amended 73 Fed.Reg. 78209 (December 22, 2008).
(g)Determination of Gauge Pressure. Gauge pressure must be determined using a hand-held manometer, magnahelic gauge, or other pressure measuring device approved by the Executive Officer. The device must be calibrated and operated in accordance with the manufacture's specifications.
(h)Alternative Test Methods. Alternative test methods may be used provided that they are approved in writing by the Executive Officer.

Cal. Code Regs. Tit. 17, § 95471

1. New section filed 6-17-2010; operative 6-17-2010 pursuant to Government Code section 11343.4 (Register 2010, No. 25).

Note: Authority cited: Sections 38501, 38510, 38560, 38560.5, 38580, 39600 and 39601, Health and Safety Code. Reference: Sections 38501, 38505, 38510, 38550, 38551, 38560, 38560.5, 39003, 39500, 39600 and 39601, Health and Safety Code.

1. New section filed 6-17-2010; operative 6-17-2010 pursuant to Government Code section 11343.4 (Register 2010, No. 25).