Cal. Code Regs. tit. 17 § 95163

Current through Register 2024 Notice Reg. No. 25, June 21, 2024
Section 95163 - Emissions and Data Calculation and Reporting Requirements
(a) The owner or operator of an affected EGU must determine the CO2 mass emissions (short tons) for the compliance period as specified under the provisions of 40 CFR § 60.5860(b)(1)-(2).
(b) The owner or operator of an affected EGU that exclusively combusts liquid fuel and/or gaseous fuel may determine the hourly CO2 mass emissions according to 40 CFR § 60.5860(a)(4)(i) through (a)(4)(vi).
(c) The owner or operator of an affected EGU (or group of affected units that share a monitored common stack) must comply with all requirements of 40 CFR § 60.5860(b)(3) for measurement and calculation of net electric output, useful thermal output, and mechanical output, and determine net energy output.
(d) Each year, any affected EGUs must submit the information specified in 40 CFR § 60.5860(d), paragraphs (1) and (3) to the Air Resources Board pursuant to section 95104(e) of this article, under the schedule specified in section 95103(e) of this article.

Cal. Code Regs. Tit. 17, § 95163

1. New section filed 9-1-2017; operative 1-1-2018 (Register 2017, No. 35).

Note: Authority cited: Sections 38510, 38530, 39600, 39601, 39602, 39607, 39607.4 and 41511, Health and Safety Code. Reference: Sections 38530, 39600 and 41511, Health and Safety Code.

1. New section filed 9-1-2017; operative 1/1/2018 (Register 2017, No. 35).