Cal. Code Regs. Tit. 17, div. 3, ch. 1, subch. 10, art. 2, subart. 5 app A

Current through Register 2024 Notice Reg. No. 25, June 21, 2024
Appendix A - to the Regulation for the Mandatory Reporting of Greenhouse Gas Emissions

Emission Factors and Calculation Data for Petroleum and Natural Gas Systems Reporting

Table 1A

Default Whole Gas Emission Factors for Onshore Petroleum and Natural Gas Production

Onshore petroleum and natural gas productionEmission factor (scf/hour/ component)
Western U.S.
Population Emission Factors All components, Gas Service:1
Valve0.121
Connector0.017
Open-ended line0.031
Pressure relief valve0.193
Low Continuous Bleed Pneumatic Device Vents21.39
High Continuous Bleed Pneumatic Device Vents237.3
Intermittent Bleed Pneumatic Device Vents213.5
Pneumatic Pumps313.3
Population Emission Factors -- All Components, Light Crude Service:4
Valve0.05
Flange0.003
Connector0.007
Open-ended Line0.05
Pump0.01
Other50.30
Population Emission Factors -- All Components, Heavy Crude Service:6
Valve0.0005
Flange0.0009
Connector (other)0.0003
Open-ended Line0.006
Other50.003

1 For multi-phase flow that includes gas, use the gas service emissions factors.

2 Emissions factor is in units of "scf/hour/device."

3 Emission Factor is in units of "scf/hour/pump."

4 Hydrocarbon liquids greater than or equal to 20°API are considered "light crude."

5 "Other" category includes instruments, loading arms, pressure relief valves, stuffing boxes, compressor seals, dump lever arms, and vents.

6 Hydrocarbon liquids less than 20°API are considered "heavy crude."

Table 1B

Default Average Component Counts for Major Onshore Natural Gas Production Equipment

Major equipment

Valves

Connectors

Open-ended lines

Pressure relief valves

Western U.S.

Wellheads113610
Separators3410662
Meters/piping145111
Compressors7317934
In-line heaters146521
Dehydrators249022

Table 1C

Default Average Component Counts for Major Crude Oil Production Equipment

Major equipment

Valves

Flanges

Connectors

Open-ended lines

Other components

Western U.S.

Wellhead510401
Separator6121000
Heater-treater8122000
Header510400

Table 2

Default Total Hydrocarbon Emission Factors for Onshore Natural Gas Processing

Onshore natural gas processing

Emission factor (scf/hour/component)

Leaker Emission Factors -- Compressor Components, Gas Service
Valve114.84
Connector5.59
Open-Ended Line17.27
Pressure Relief Valve39.66
Meter19.33
Leaker Emission Factors -- Non-Compressor Components, Gas Service
Valve16.42
Connector5.71
Open-Ended Line11.27
Pressure Relief Valve2.01
Meter2.93

1 Valves include control valves, block valves and regulator valves.

Table 3

Default Total Hydrocarbon Emission factors for Onshore Natural Gas Transmission Compression

Onshore Natural Gas Transmission compression

Emission factor (scf/hour/component)

Leaker Emission Factors -- Compressor Components, Gas Service
Valve114.84
Connector5.59
Open-Ended Line17.27
Pressure Relief Valve39.66
Meter19.33
Leaker Emission Factors -- Non-Compressor Components, Gas Service
Valve16.42
Connector5.71
Open-Ended Line11.27
Pressure Relief Valve2.01
Meter2.93
Population Emission Factors -- Gas Service
Low Continuous Bleed Pneumatic Device Vents21.37
High Continuous Bleed Pneumatic Device Vents218.20
Intermittent Bleed Pneumatic Device Vents22.35

1 Valves include control valves, block valves, and regulator valves.

2 Emission Factor is in units of "scf/hour/component."

Table 4

Default Total Hydrocarbon Emission Factors for Underground Natural Gas Storage

Underground natural gas storage

Emission factor (scf/hour/component)

Leaker Emission Factors -- Storage Station, Gas Service
Valve114.84
Connector5.659
Open-Ended Line17.27
Pressure Relief valve39.66
Meter19.33
Population Emission Factors -- Storage Wellheads, Gas Service
Connector0.01
Valve10.1
Pressure Relief Valve0.17
Open Ended Line0.03
Population Emission Factor -- Other Components, Gas Service
Low Continuous Bleed Pneumatic Device Vents21.37
High Continuous Bleed Pneumatic Device Vents218.20
Intermittent Bleed Pneumatic Device Vents22.35

1 Valves include control valves, block valves and regulator valves.

2 Emission Factor is in units of "scf/hour/device.

Table 5

Default Methane Emission Factors for Liquefied Natural Gas (LNG) Storage

LNG Storage

Emission factor (scf/hour/component)

Leaker Emission Factors -- LNG storage Components, Gas and Liquids Service
Valve1.19
Pump Seal4.00
Connector0.34
Other11.77
Population Emission Factors -- LNG Storage Compressor, Gas Service
Vapor Recovery Compressor24.17

1 "other" equipment type should be applied for any equipment type other than connectors, pumps, or valves.

2 Emission Factor is in units of "scf/hour/compressor."

Table 6

Default Methane Emission Factors for LNG Import and Export Equipment

LNG import and export equipment

Emission factor (scf/hour/component)

Leaker Emission Factors -- LNG Terminals Components, Gas and Liquid Service
Valve1.19
Pump Seal4.00
Connector0.34
Other11.77
Population Emission Factors -- LNG Terminal Compressor, Gas Service
Vapor Recovery Compressor24.17

1 "other" equipment type should be applied for any equipment type other than connectors, pumps, or valves.

2 Emission Factor is in units of "scf/hour/compressor."

Table 7

Default Methane Emission Factors for Natural Gas Distribution

Natural gas distribution

Emission factor (scf/hour/component)

Leaker Emission Factors -- Above Grade M&R at City Gate Stations1 Components
Connector1.69
Block Valve0.557
Control Valve9.34
Pressure Relief Valve0.27
Orifice Meter0.212
Regulator0.772
Open-ended Line26.131
Population Emission Factors -- Below Grade M&R2 Components, Gas Service3
Below Grade M&R Station, Inlet Pressure >300 psig1.30
Below Grade M&R Station, Inlet Pressure 100 to 300 psig0.20
Below Grade M&R Station, Inlet Pressure <100 psig0.10

Natural gas distribution

Emission factor (scf/meter-hour)

Population Emission Factors -- Customer Meters
Residential0.01582
Commercial0.00547
Industrial0.00547

Natural gas distribution

Emission factor (scf/hour/component)

Population emission Factors -- Distribution Mains, Gas Service4
Unprotected steel12.58
Protected Steel0.35
Plastic1.13
Cast Iron27.25
Population Emission Factors -- Distribution Services, Gas Service5
Unprotected Steel0.19
Protected Steel0.02
Plastic0.001
Copper0.03

1 City gate stations at custody transfer and excluding customer meters.

2 Excluding customer meters.

3 Emission Factor is in units of "scf/hour/station."

4 Emission Factor is in units of "scf/hour/mile."

5 Emission factor is in units of "scf/hour/number of services."

Cal. Code Regs. Tit. 17, div. 3, ch. 1, subch. 10, art. 2, subart. 5 app A

1. New Appendix A filed 12-19-2012; operative 1-1-2013 pursuant to Government Code section 11343.4 (Register 2012, No. 51). For prior history of Appendix A, see Register 2011, No. 50.
2. Amendment of Appendix A, Table 7 filed 12-31-2014; operative 1-1-2015 pursuant to Government Code section 11343.4(b)(3) (Register 2015, No. 1).
3. Amendment of table 7 adding footnote reference filed 9-1-2017; operative 1-1-2018 (Register 2017, No. 35).
1. New Appendix A filed 12-19-2012; operative 1-1-2013 pursuant to Government Code section 11343.4 (Register 2012, No. 51). For prior history of Appendix A, see Register 2011, No. 50.
2. Amendment of Appendix A, Table 7 and amendment of Appendix B, items 2., 10.1(c) and 12.3(d)-(e) filed 12-31-2014; operative 1-1-2015 pursuant to Government Code section 11343.4(b)(3) (Register 2015, No. 1).
3. Amendment of table 7 adding footnote reference filed 9-1-2017; operative 1/1/2018 (Register 2017, No. 35).