The following minimum specifications apply to the specified ADFs that are sold, offered for sale, supplied for use in California, or produced in or imported into California:
Table A.3. Fuel Specifications for B100 Blendstock
Property | Value | Test Method |
Unadditized Cetane Number | >=47 | ASTM D613-14, ASTM D6890-13be1, ASTM D7170-14; or ASTM D7668-14a |
API Gravity | >=27 degrees API | ASTM D287-12b |
Sulfur | [LESS THAN EQUAL TO]15 ppm | ASTM D5453-93 |
Cal. Code Regs. Tit. 13, § 2293.7
Note: Authority cited: Sections 39600, 39601, 43013, 43018 and 43101, Health and Safety Code; and Western Oil and Gas Ass'n. v. Orange County Air Pollution Control District, 14 Cal. 3d 411, 121 Cal.Rptr. 249 (1975). Reference: Sections 39000, 39001, 39002, 39003, 39010, 39500, 40000, 43000, 43016, 43018, 43026, 43101 and 43865, Health and Safety Code; and Western Oil and Gas Ass'n. v. Orange County Air Pollution Control District, 14 Cal. 3d 411, 121 Cal.Rptr. 249 (1975).