ARKANSAS WATER WELL CONSTRUCTION COMMISSION RULES AND REGULATIONS 2005
[RESERVED]
Contractor Licenses | |
Drilling and Pump System License ..................................... | .$.200.00 |
Pump System License ......................................................... | ...... 50.00 |
Registration Certificates | |
Driller Registration Certificate ........................................... | ...... 70.00 |
Pump Installer Registration Certificate ............................... | ...... 70.00 |
Apprentice Certificate ......................................................... | ...... 70.00 |
Examination Fees ....................................................................... | ...... 25.00 |
Rig permit .................................................................................. | ...... 80.00 |
Official Copy Construction Report ............................................ | ...... 10.00 |
EXAMPLE 1: A line shaft, is replaced by another line shaft, and the replacement has no obvious physical defects or is not of an inferior or superior quality than the first. No report required.
EXAMPLE 2: A plastic coupling, installed below ground level, is replaced by a galvanized coupling. A report is required.
NOTE: Construction requirements vary according to type of formation, type of well, intended use. Please review the both the general requirements and Section 6, "SPECIAL WELL CONSTRUCTION TECHNIQUES" for the type of well you are working on.
POTENTIAL SOURCES OF CONTAMINATION | MINIMUM LATERAL DISTANCES FOR CLAY AND LOAM SOILS. |
Cess Pools | 100 Feet |
Leaching Pit | 100 Feet |
Pit Privy | 100 Feet |
Subsurface Seepage Tile | 100 Feet |
Manure Piles | 100 Feet |
Septic Tank | 100 Feet |
Sewers (Cast iron with water tight, leaded or mechanical joints) | 50 Feet |
Footing Drains (No connection to a sewer or a sump handling sewage) | 10 Feet |
Pump House Floor Drain (Cast iron with water tight joints and having free fall discharge to ground surface) | 2 Feet |
When the upper formations are more pervious, the lateral distances shall be increased (i.e., double the distance for highly pervious gravel formations).
1Ten feet from ground surface or one foot minimum in to the consolidated formation means that wells must be cased at least ten feet. Wells will never have less than 5 feet of cement or Bentonite grout in the annulus. Wells must also be cased at least one foot into consolidated formations. Minimum of one foot into consolidated rock means that many times even thought the formation is consolidated, ground water, at a particular depth would be undesirable and additional casing and grout to a depth greater than one foot into consolidated formation is required.
* The above steps are not meant to be all inclusive. The contractor remains responsible and liable for damages to the well or wells in the immediate vicinity resulting from hydrofracturing, even though the Contractor may have complied with these regulations.
size of closed loop system, the land area available, soils/formation, climate, and seasonal variation in ground temperature, etc. There are three types of closed loop heat pump well systems:
Arkansas Water Well Construction Commission
101 East Capitol Avenue, Suite 350
Little Rock, Arkansas 72201
phone (501) 682-1025
Ask for the RCRA book on monitor wells - cost $22.00.
For the purpose of these rules and regulations, the following definitions shall apply:
SIZE | EXTERNAL | INTERNAL | THICKNESS | WEIGHT PLAIN END | (LBS./FT.) THREADED AND COUPLED |
1.00 | 1.315 | 1.049 | .133 | 1.68 | 1.70 |
1.25 | 1.660 | 1.049 | .140 | 2.27 | 2.30 |
1.50 | 1.900 | 1.610 | .145 | 2.72 | 2.75 |
2.00 | 2.375 | 2.061 | .154 | 3.65 | 3.75 |
2.50 | 2.875 | 2.469 | .203 | 5.79 | 5.90 |
3.00 | 3.500 | 3.068 | .216 | 7.58 | 7.70 |
3.50 | 4.000 | 3.548 | .226 | 9.11 | 9.25 |
4.00 | 4.500 | 4.026 | .237 | 10.70 | 11.00 |
5.00 | 5.563 | 5.047 | .258 | 14.62 | 15.00 |
Table 2. Chlorine Compound Required to Produce a 50-mg / l Solution in 100 ft (30.5 m) of Water-Filled Casing*
Casing Diameter | Volume 100ft. (30.5 m) | 65% HTH, Perchloron, etc. (dry weight) | 25% Chloride of Lime (dry weight)H | 5.25% Purex, Chlorox, etc.(sodium hypochlorite) (liquid measure) | |||||
in | mm | 3 gal m | oz | g | oz | g | oz | l | |
2 | 51 | 16.3 | 0.06 | 0.2 | 5.7 | 0.5 | 14.2 | 2 | 0.06 |
4 | 102 | 65.3 | 0.25 | 0.7 | 19.8 | 2 | 56.7 | 9 | 0.3 |
6 | 152 | 147 | 0.56 | 2 | 56.7 | 4 | 113 | 20 | 0.6 |
8 | 203 | 261 | .99 | 3 | 85.1 | 7 | 198 | 34 | 1.0 |
10 | 254 | 408 | 1.5 | 4 | 113 | 11 | 312 | 56 | 1.7 |
12 | 305 | 588 | 2.2 | 6 | 170 | 16 | 454 | 80 | 2.4 |
16 | 406 | 1,045 | 4.0 | 11 | 312 | 28 | 794 | 128 | 3.8 |
20 | 508 | 1,632 | 6.2 | 17 | 482 | 43 | 1,219 | 214 | 6.4 |
24 | 610 | 2,350 | 8.9 | 24 | 680 | 63 | 1,786 | 298 | 8.7 |
Note: Liquid sodium hypochlorite in a 12-percent solution is often sold for use in water and wastewater treatment plants, and as a commercial bleach or for use in swimming pools. Utilizing a solution of this nature would call for a liquid (chemical) measure equal to one-half the volumes presented in column 5.
*EPA recommends a minimum concentration of 100 mg/ l available chlorine. To obtain this concentration, double the amounts indicated.
Where a dry chemical is used, it should be mixed with water to form a chlorine solution before putting it into the well.
Table 3 How to Sanitize a Water System to 400 ppm using Autotrol's Well Sanitizer Pellets. Autotrol's pellets contain 70% calcium hypochlorite and 30% inert material.
Well Diameter-Inches | For each 100 feet of water depth use* | ||
Weight of Pellets lbs. - oz. | Cups of Pellets | Number of Pellets | |
2 | 0 - 1.5 | 1 / 4 | 40 |
3 | 0 - 3.0 | 2 / 5 | 80 |
4 | 0 - 6.0 | 3 / 4 | 140 |
5 | 0 - 8.0 | 1 | 200 |
6 | 0 - 12.0 | 1 - 1/2 | 300 |
8 | 1 - 5.0 | 2 - 1/2 | 500 |
10 | 2 - 0 | 4 | 800 |
12 | 3 - 0 | 6 | - - - |
24 | 12 - 0 | 24 | - - - |
36 | 26 - 0 | - - - | - - - |
* To produce a 400 PPM chlorine dosage
Note: Pellets Weight = 1.14 gram each, 25 pellets/oz., 400 pellets/lb.
1 cup of pellets = 1/2 lb., or 8 oz., or 200 pellets
Autotrol Corporation's Well Sanitizer chlorinating pellets can be used for well, storage tank, or cistern sanitization. The amount of pellets used will depend on the amount of water in the system to be sanitized. To produce a 400 ppm chlorine concentration, to sanitize a water system, use one-half (1/2) pound chlorination pellets for each 100 gallons of water in the system (1/2 lb/100 gal = 8 oz/100 gal = 200 pellets/100 gal = 1 cup pellets/100 gal). Table 3 shows how many pellets to use per 100 feet of water in various diameter wells.
Drilled Wells
Note:
Large Diameter Bored Wells
Calculate the volume of water in well by determining the total cubic inches or cubic feet of water in the well. Each 231 cubic inches of water is equal to one gallon. Each cubic foot of water is 7.5 gallons of water. Use 1/2 pound of chlorine pellets for each 100 gallons of water in well. Dissolve pellets in clean, plastic pail and add to well. Pour two cups of pellets directly into well. Connect a garden hose to a faucet in water system and run water from hose back down well. When strong chlorine odor is present in hose water, wash down sides of well with chlorinated water. Proceed with steps Nos. 6, 7 and 8 of instructions for Drilled Wells.
Springs and Cisterns
Mix about 1/2 cup of pellets in 5 gallons of water use this to scrub the walls of the spring box or holding tank. With a constant flow of fresh water from the spring there is probably no way of detaining the chlorine solution in the reservoir for more than a few minutes. However, the chlorinated water should flow through the pipeline to disinfect the distribution system. Cisterns can be disinfected in the same way but a source of clean water will be needed to flush the dirty waste out of the system.
Note: This product is intended to sanitize a water supply system that has been temporarily contaminated, and is not intended to solve a recurring contamination problem.
NOTE: These regulations are the minimum requirements for water wells constructed in Arkansas.
< For additional information pertaining to Public or Semi-Public Water Systems contact the Arkansas Department of Health, 661-2000.
< For information regarding water use reporting, water rights, and ground water diversions contact the Arkansas Natural Resources Commission, 682-1611.
< For information on having your well water sampled contact your local county sanitarian, county health unit.
< For additional information on water well construction or if you believe you have a complaint contact the Arkansas Water Well Construction Commission.
< For Underground Storage Tank information contact the U.S.T. Division at Arkansas Department of Pollution Control and Ecology, 562-7444.
096.00.06 Ark. Code R. 001