Section R9-7-533 - Radiation SurveysA. A licensee shall conduct surveys with a calibrated and operable radiation survey instrument that meets the requirements of R9-7-504.B. Using a survey instrument that complies with subsection (A), the licensee shall conduct a survey of the radiographic exposure device and the guide tube after each exposure before approaching the device or the guide tube. The survey shall be performed to determine that the sealed source is in the shielded position before the radiographer or radiographer's assistant exchanges films, repositions the exposure head, or dismantles the equipment.C. The licensee shall conduct a survey of the radiographic exposure device with a calibrated radiation survey instrument any time the source is exchanged or the device is placed in a storage area, as defined in R9-7-102, to ensure that the sealed source is in the shielded position.D. The licensee shall maintain a record of each exposure device survey conducted before the device is placed in storage under subsection (C), if that survey is the last one performed during the workday. Each record shall be maintained for three years after the record is made.Ariz. Admin. Code § R9-7-533
New Section R9-7-533 recodified from R12-1-533 at 24 A.A.R. 813, effective March 22, 2018 (Supp. 18-1).