Wastewater Source (Add together all wastewater source line items applicable to the facility per applicable unit.) | Applicable Unit | Sewage Design Flow per Applicable Unit, Gallons Per Day |
Airport For each passenger (average daily number), add For each employee, add | Passenger (average daily number) | 4 |
Employee | 15 | |
Auto Wash | Facility | Per manufacturer, if consistent with this Chapter |
Bar/Lounge | Seat | 30 |
Barber Shop | Chair | 35 |
Beauty Parlor | Chair | 100 |
Bowling Alley (snack bar only) | Lane | 75 |
Camp Day camp, no cooking facilities Campground, overnight, flush toilets Campground, overnight, flush toilets and shower Campground, luxury Camp, youth, summer, or seasonal | Camping unit Camping unit Camping unit Person Person | 30 75 150 100-150 50 |
Church Without kitchen With kitchen | Person (maximum attendance) Person (maximum attendance) | 5 7 |
Country Club | Resident Member Nonresident Member | 100 10 |
Dance Hall | Patron | 5 |
Dental Office | Chair | 500 |
Dog Kennel | Animal, maximum occupancy | 15 |
Dwelling For determining design flow for sewage treatment facilities under R18-9-B202(A)(9)(a) and sewage collection systems under R18-9-E301(D) and R18-9-B301(K), excluding peaking factor. | Person | 80 |
Dwelling For on-site wastewater treatment facilities per R18-9-E302 through R18-9-E323: | ||
Apartment Building | ||
1 bedroom | Apartment | 200 |
2 bedroom | Apartment | 300 |
3 bedroom | Apartment | 400 |
4 bedroom | Apartment | 500 |
Seasonal or Summer Dwelling (with recorded seasonal occupancy restriction) | Resident | 100 |
Single Family Dwellings (for both conventional and alternative systems) | see R18-9-A314(4)(a) | see R18-9-A314(4)(a) |
Other than Single Family Dwelling, the greater flow value based on: | ||
Bedroom count | 300 | |
1-2 bedrooms | Bedroom | 150 |
Each bedroom over 2 | Bedroom | 25 |
Fixture count | Fixture unit | |
Fire Station | Employee | 45 |
Hospital | ||
All flows | Bed | 250 |
Kitchen waste only | Bed | 25 |
Laundry waste only | Bed | 40 |
Hotel/motel (assuming outsourced linen laundry service) | ||
Without kitchen | Bed (2 person) | 50 |
With kitchen | Bed (2 person) | 60 |
Industrial facility | ||
Without showers | Employee | 25 |
With showers | Employee | 35 |
Cafeteria, add | Employee | 5 |
Institutions | ||
Resident | Person | 75 |
Nursing home | Person | 125 |
Rest home | Person | 125 |
Laundry | ||
Self service | Wash cycle | 50 |
Commercial | Washing machine | Per manufacturer, if consistent with this Chapter |
Office Building | Employee | 20 |
Park (temporary use) | ||
Picnic, with showers, flush toilets | Parking space | 40 |
Picnic, with flush toilets only | Parking space | 20 |
Recreational vehicle, no water or sewer connections | Vehicle space Vehicle space | 75 100 |
Recreational vehicle, with water and sewer connections | Space | 250 |
Mobile home/Trailer | ||
Restaurant/Cafeteria For each employee, add With toilet, add Kitchen waste - full plated service, add Kitchen waste - disposable service, add Garbage disposal, add Cocktail lounge, add | Employee Customer Meal Meal Meal Customer | 20 7 6 2 1 2 |
Restroom, public | Toilet | 200 |
School | ||
Staff and office | Person | 20 |
Elementary, add | Student | 15 |
Middle and High, add | Student | 20 |
with gym & showers, add | Student | 5 |
with cafeteria, add | Student | 3 |
Boarding, total flow | Person | 100 |
Service Station with toilets | First bay | 1000 |
Each additional bay | 500 | |
Shopping Center, no food or laundry | Square foot of retail space | 0.1 |
Store For each employee, add | Employee | 20 |
Public restroom, add | Square foot of retail space | 0.1 |
Swimming Pool, Public | Person | 10 |
Theater | ||
Indoor | Seat | 5 |
Drive-in | Car space | 10 |
Note: Unit flow rates published in standard texts, literature sources, or relevant area or regional studies are considered by the Department, if appropriate to the project.
Ariz. Admin. Code tit. 18, ch. 9, art. 3, pt. E, tbl. 1