Ariz. Admin. Code § 18-5-225

Current through Register Vol. 30, No. 50, December 13, 2024
Section R18-5-225 - Pumps and Motors
A. A pump and motor shall be provided for each water circulation system. The pump shall be sized to meet but not to exceed the flow rate required for filtering against the total head developed by the complete water circulation system. The pump shall be sized to comply with the turnover rate prescribed in R18-5-223(B).
B. Pumps and motors shall be readily and easily accessible for inspection, maintenance, and repair. When the pump is below the waterline, valves shall be installed on permanently connected suction and discharge lines. The valves shall be readily and easily accessible for maintenance and removal of the pump.
C. Each motor shall have an open, drip-proof enclosure. Each motor shall be constructed electrically and mechanically to perform satisfactorily and safely under the conditions of load in the environment normally encountered in swimming pool or spa installations. Each motor shall be capable of operating the pump under full load with a voltage variation of ± 10% from the nameplate rating. Each motor shall have thermal or current overload protection to provide locked rotor and running protection. Thermal or current overload protection may be built into the motor or in the line starter.
D. The pump shall be equipped with an emergency shut-off switch that is located within the swimming pool or spa enclosure to cut off power to the water circulation system if someone is entrapped on a main drain or suction outlet.

Ariz. Admin. Code § R18-5-225

Adopted effective February 19, 1998 (Supp. 98-1).