Ariz. Admin. Code § 18-5-215

Current through Register Vol. 30, No. 24, June 14, 2024
Section R18-5-215 - Ladders
A. At least one ladder shall be provided in the deep area of a public or semipublic swimming pool. If the width of the deep area of a swimming pool is greater than 20 feet, then one ladders shall be located on opposite sides of the deep area.
B. A swimming pool or spa ladder shall be equipped with two handrails.
C. All treads on ladders shall have slip-resistant surfaces.
D. Ladder treads shall have a minimum horizontal depth of 1 1/2 inches. The distance between ladder treads shall range from a minimum of 7 inches to a maximum of 12 inches.
E. Below the waterline, there shall be a clearance of not more than 6 inches and not less than 3 inches between any ladder tread edge and the wall as measured from the side of the tread closest to the wall.

Ariz. Admin. Code § R18-5-215

Adopted effective February 19, 1998 (Supp. 98-1).