Section R18-5-210 - Walls
A. Where a racing lane terminates in a swimming pool, the wall shall be plumb to a minimum depth of 5 feet below the waterline. Below the 5-foot depth, the wall shall be radiused to join the floor.
B. There shall be no projections from a swimming pool or spa wall except for coping, cantilevered deck, ladders, and steps.
C. An underwater seat shall comply with the following:
1. The edges of an underwater seat shall be outlined with a sharply contrasting colored tile or other material that is clearly visible from the deck adjacent to the underwater seat;
2. An underwater seat shall have a slip-resistant surface;
3. An underwater seat shall be located outside of the deep area of a swimming pool that is equipped for diving. An underwater seat may be located in the deep area of a swimming pool that is not equipped for diving provided the underwater seat is either completely recessed into the swimming pool wall, shaped to be compatible with the shape of the swimming pool wall, or in a corner of the swimming pool;
4. The maximum depth of an underwater seat is 24 inches below the waterline. The minimum depth of an underwater seat is 12 inches below the waterline; and
5. The maximum width of an underwater seat is 20 inches.
D. If a spa is located immediately adjacent to a swimming pool, the separating wall between the spa and the swimming pool shall be no more than 8 inches wide. The top of the separating wall shall be no lower than the level of the coping of the swimming pool. If a separating wall is more than 8 inches wide, then the deck width shall comply with R18-5-217(D). A spa shall not be located immediately adjacent to the deep area of a swimming pool.
E. Coping or cantilevered deck may project from a swimming pool or spa wall to provide a handhold for users. The coping or deck shall be rounded, have a slip-resistant surface finish, and shall not exceed 3 1/2 inches in thickness. The overhang of the coping or deck shall not exceed 2 inches or be less than 1 inch. All corners created by coping or cantilevered deck shall be rounded in both the vertical and horizontal dimensions to eliminate sharp corners.

Ariz. Admin. Code § R18-5-210

Adopted effective February 19, 1998 (Supp. 98-1).