17 Alaska Admin. Code § 15.183

Current through May 31, 2024
Section 17 AAC 15.183 - Underground utility accommodation on runways

An underground facility crossing of a runway must be installed by boring, coring, or jacking under the runway surface. Wet-boring is prohibited. The department may allow trenched or open-cut construction where untrenched construction is not practical. An underground facility crossing in a department right-of-way must conform to the specifications set out in any special provisions of the utility permit.

17 AAC 15.183

Eff. 7/15/2009, Register 191

Authority:AS 02.15.020

AS 02.15.102

AS 02.15.106

AS 44.42.020

AS 44.42.030