Section 535-X-11-.09 - Heating And/Or Air Conditioning Plan Drawing Requirements

The heating and air conditioning plans submitted pursuant to Rule 535-X-11-.07 of this chapter must:

(a) Show location of all equipment, appliances, and installations.
(b) Indicate that appliances, units, or equipment are listed or labeled by an approved listing agency.
(c) Provide heat loss calculations.
(d) Provide manufacturer's name, make, model number, BTU, and input rating of all appliances and equipment.
(e) Indicate duct and register locations, size, and materials, including ducts for air-conditioning units.
(f) Indicate clearances from combustible material or surfaces for all appliances, equipment, ducts, flues, and chimneys.
(g) Show method of providing required combustion air and return air.
(h) Show location of flues, vents, and chimneys and clearances for air intakes, and other vents, flues, etc.
(i) Provide details and indicate approvals for damper in ducts penetrating fire separation walls, floors, and ceilings, etc.
(j) Indicate method of testing.
(k) Specify method of securing every appliance and their components to avoid displacement and movement from vibration and shock.

Author: Harold A. Hendrix

Ala. Admin. Code r. 535-X-11-.09

Filed February 6, 1990.