Ala. Admin. Code r. 170-X-2-.07

Current through Register Vol. 42, No. 12, September 30, 2024
Section 170-X-2-.07 - ABC Code Supplements

To minimize reoccurring problems on public construction and improvement projects, from time to time the Commission will adopt and publish specific design and construction requirements or recommendations to supplement the State Building Code. The following requirements and recommendations are adopted and bound at the end of this chapter:

(a) ABC Code Supplement No. 1, LABELING OF FIRE DOORS AND FRAMES

Author: Stedmann B. McCollough, Director

Ala. Admin. Code r. 170-X-2-.07

Repealed and Replaced: Filed August 29, 1997; effective October 3, 1997. ATTACHMENT 170-X-2-.07(a) ABC CODE SUPPLEMENT No. 1 LABELING OF FIRE DOORS AND FRAMES All door openings in fire resistive walls and partitions requiring a rating shall be protected by assemblies which include doors, frames, hardware, closing devices, anchorage, sills, etc., installed in accordance with the National Fire Protection Association (NFPA) 80, Standard for "Fire Doors and Fire Windows" and the State Building Code. To further clarify the basic requirements and/or the correct method of labeling that will be acceptable to the Alabama Building Commission, the labels shall include the following: 1. Accessibility: Each component shall bear a label located so as to be accessible after installation. 2. Permanence: Each component shall bear a label of a type of material and be so attached that the life of the label and the attachment thereof can reasonably be expected to equal the life of the component to which it is attached. Labels shall be raised or embossed on metal labels or stamped into metal frames. Plastic or paper labels are unacceptable. 3. Legibility: The label design shall be such that it can be visible and legible at all times and must be clean of any paint or other coverage making the label illegible. 4. Fire Resistance: All approved labels on doors and on frames shall include thereon the fire resistance rating in hours and/or minutes for which the door or frame is labeled. Labels on frames with transoms or sidelights must identify that the opening assembly includes same. 5. Other Requirements: The labels or stamps applied to frames must be provided by a manufacturer that has been approved by a laboratory or organization to provide testing and follow-up services for fire-rated opening assemblies. Author: Stedmann B. McCollough, Director Statutory Authority: Code of Ala. 1975, §§ 41-9-141; 41-9-161. New: Filed August 29, 1997; effective October 3, 1997.

Statutory Authority:Code of Ala. 1975, §§ 41-9-141, 41-9-161.