Section 51-11C-405054 - Table C405.4.2(2)-Interior lighting power allowances-Space-by-space method

Table C405.4.2(2)

Interior Lighting Power Allowances-Space-by-Space Method

Common Space-by-Space Typesa, j

LPD (w/ft2)

Atrium - Less than 20 feet in height

0.39

Atrium - 20 to 40 feet in height

0.48

Atrium - Above 40 feet in height

0.60

Audience/seating area - Permanenti

In an auditorium

In a gymnasium

In a motion picture theater

In a penitentiary

In a performing arts theater

In a religious building

In a sports arena

Otherwise

0.61

0.23

0.27

0.67

1.16

0.72

0.33

0.23

Banking activity areai

0.61

Breakroom (see lounge/breakroom)

Classroom/lecture hall/training room

In a penitentiary

Otherwiseh

0.89

0.71

Computer room, data center

0.94

Conference/meeting/multipurpose

0.97

Confinement cell

0.70

Copy/print room

0.31

Corridor

In a facility for the visually impaired (and not used primarily by the staff)b

In a hospital

In a manufacturing facility

Otherwisec, i

0.71

0.71

0.41

0.41

Courtroomc

1.20

Dining area

In a penitentiary

In a facility for the visually impaired (and not used primarily by the staff)b

In a bar/lounge or leisure diningi

In cafeteria or fast food dining

In a family dining areai

Otherwise

0.42

1.27

0.86

0.40

0.60

0.43

Electrical/mechanical

0.43

Emergency vehicle garage

0.52

Food preparation

1.09

Guest rooma, b

0.41

Laboratory

In or as a classroom

1.11

Otherwise

1.33

Laundry/washing area

0.53

Loading dock, interior

0.88

Lobbyc

In a facility for the visually impaired (and not used primarily by the staff)b

For an elevator

In a hotel

In a motion picture theater

In a performing arts theater

Otherwise

1.69

0.65

0.51

0.23

1.25

0.84

Locker room

0.52

Lounge/breakroomi

In a health care facilityc, i

Otherwisei

0.42

0.59

Office

Enclosed [LESS THAN EQUAL TO] 250

Enclosed [GREATER THAN] 250

Open plan

0.74

0.66

0.61

Parking area, interior

0.15

Pharmacy area

1.66

Restroom

In a facility for the visually impaired (and not used primarily by the staff)b

Otherwisei

1.26

0.63

Sales area

1.05

Seating area, general

0.23

Stairway (see space containing stairway)

Stairwellc, i

0.49

Storage room

[LESS THAN] 50 ft2

50-100 ft2

All other storage

0.51

0.38

0.38

Vehicular maintenance

0.60

Workshop

1.26

Building Specific Space-by-Space Typesa

LPD (w/ft2)

Automotive (see vehicular maintenance)

Convention center - Exhibit spacei

0.61

Dormitory living quartersa, b

0.50

Facility for the visually impairedb

In a chapel (and not used primarily by the staff)b

In a recreation room (and not used primarily by the staff)b

0.70

1.77

Fire stations

Sleeping quarters

0.23

Gymnasium/fitness center

In an exercise area

In a playing area

0.90

0.85

Health care facilityc, i

In an exam/treatment room

In an imaging room

In a medical supply room

In a nursery

In a nurse's station

In an operating room

In a patient room

In a physical therapy room

In a recovery room

1.40

0.94

0.62

0.92

1.17

2.26

0.68

0.91

1.25

Library

In a reading areai

In the stacks

0.96

1.10

Manufacturing facility

In a detailed manufacturing area

In an equipment room

In an extra high bay area (greater than 50-foot floor-to-ceiling height)

In a high bay area (25 - 50-foot floor-to-ceiling height)

In a low bay ([LESS THAN] 25-foot floor-to-ceiling height)

0.80

0.76

1.42

1.24

0.86

Museum

In a general exhibition areai

In a restoration room

0.31

1.10

Performing arts theater dressing/fitting room

0.41

Post office - Sorting area

0.76

Religious buildings

In a fellowship halli

In a worship/pulpit/choirareai

0.54

0.85

Retail facilities

In a dressing/fitting room

In a mall concourse

0.51

0.82

Sports arena - Playing area

For a Class 1 facilityd

For a Class 2 facilitye

For a Class 3 facilityf

For a Class 4 facilityg

2.94

2.01

1.30

0.86

Transportation

In a baggage/carousel area

In an airport concourse

At a terminal ticket counteri

0.39

0.25

0.51

Warehouse - Storage area

For medium to bulky palletized items

For smaller, hand-carried items

0.33

0.69

For SI: 1 foot = 304.8 mm, 1 watt per square foot = 10.76 W/m2

. a In cases where both a common space type and a building area specific space type are listed, the building area specific space type shall apply.

b A facility for the visually impaired is a facility that is licensed or will be licensed by local or state authorities for senior long-term care, adult daycare, senior support or people with special visual needs.

c Additional lighting power allowance of 0.2 watts per square foot for the purpose of highlighting art or exhibits. This additional power allowance shall be permitted only where the specified lightinged in addition to and controlled separately from general lighting in accordance with Section C405.2.6. This additional power allowance shall be used only for the specified luminaires and shused for any other purpose and it shall not be added to any other space or the interior power allowance.

d Class I facilities consist of professional facilities; and semiprofessional, collegiate or club facilities with seating for 5,000 or more spectators.

e Class II facilities consist of collegiate and semiprofessional facilities with seating for fewer than 5,000 spectators; club facilities with seating between 2,000 and 5,000 spectators; and amateur league and high school facilities with seating for more than 2,000 spectators.

f Class III facilities consist of club, amateur league and high school facilities with seating for 2,000 or fewer spectators.

g Class IV facilities consist of elementary school and recreational facilities; and amateur league and high school facilities without provisions for spectators.

h For classrooms, additional lighting power allowance of 4.50 W/lineal foot of white or chalk boards for directional lighting dedicated to white or chalk boards.

i Additional lighting power allowance of 0.15 W/ft2 for ornamental lighting. Qualifying ornamental lighting includes luminaires that are specifically used in a decorative manner. This additional power shall be permitted only where the specified lighting is installed in addition to and controlled separately from display or general lighting in accordance with Section C405.2.6. This additional power shall be used only for the specified luminaires and it shall not be added to any other space or the interior power allowance.

j Where a space is designated as unfinished, neither the area nor the lighting power in the space shall be calculated as part of the LPA.

Wash. Admin. Code § 51-11C-405054

Amended by WSR 16-03-072, Filed 1/19/2016, effective 7/1/2016
Amended by WSR 19-24-040, Filed 11/26/2019, effective 7/1/2020
Amended by WSR 20-21-080, Filed 10/19/2020, effective 2/1/2021
Amended by WSR 22-14-091, Filed 7/1/2022, effective 7/1/2023
Amended by WSR 24-16-145, Filed 8/7/2024, effective 9/7/2024

Statutory Authority: RCW 19.27A.020, 19.27A.025 and chapters 19.27 and 34.05 RCW. 13-04-056, § 51-11C-405054, filed 2/1/13, effective 7/1/13.