Okla. Admin. Code § 252:100-17-5

Current through Vol. 42, No. 1, September 16, 2024
Section 252:100-17-5 - Incinerator design and operation requirements

An incinerator subject to this part shall be designed and built with a primary combustion chamber that maintains a temperature of at least 800oF in the primary combustion chamber at all times when refuse is being incinerated, and a secondary combustion chamber(s) that is adequately designed and operated to combust gaseous and particulate matter suspended in the exhaust gas stream from the primary combustion chamber. The combustion device in each combustion chamber shall be in operation at all times when refuse is being incinerated.

Okla. Admin. Code § 252:100-17-5

Amended at 15 Ok Reg 2591, eff 6-25-98; Amended at 17 Ok Reg 3353, eff 7-24-00 (emergency); Amended at 18 Ok Reg 1489, eff 6-1-01; Amended at 27 Ok Reg 2134, eff 7-11-10