N.H. Admin. Code § Saf-C 5024.04

Current through Register No. 44, October 31, 2024
Section Saf-C 5024.04 - Prohibitions
(a) Shells shall be carried from the storage area to the discharge site only by their bodies, and never by their fuses.
(b) The safety cap protecting the fuse shall not be removed by the operator responsible for igniting the fuse until immediately before the shell shall be fired.
(c) No smoking or open flames shall be allowed in the shell storage area if shells are present.
(d) No attempt shall be made to repair a damaged shell or to attempt to dismantle a dry shell. The operator shall contact the supplier for proper disposal instructions.
(e) Display fireworks that have become wet shall not be utilized even if dried out.
(f) Displays shall not be set up during any rain or snow storm or displayed during any electrical storm or when the wind reaches a velocity of more than 20 miles per hours.

N.H. Admin. Code § Saf-C 5024.04

(See Revision Note at Chapter heading for Saf-C 5000) #6055, eff 7-1-95; amd by #7481, eff 4-25-01; paragraphs (a)-(d) and (f) EXPIRED: 7-1-03; amd by #8117, INTERIM, eff 7-14-04; paragraphs (a)-(d) and (f) EXPIRED: 1-10-05; amd by #8261, eff 1-21-05, amd by #9471, INTERIM, eff 5-15-09, EXPIRED: 11-11-09

New. #9765-A, eff 8-2-10

Amended by Volume XXXIX Number 16, Filed April 18, 2019, Proposed by #12738, Effective 4/30/2019, Expires 4/30/2029.